background image

for drinking water and heating installation
Model

2275.10

en_INT

Easytop ball valve with SC-Contur

Instructions for Use

Summary of Contents for Easytop 2275.10

Page 1: ...for drinking water and heating installation Model 2275 10 en_INT Easytop ball valve with SC Contur Instructions for Use...

Page 2: ...Easytop ball valve with SC Contur 2 from 21...

Page 3: ...nts 11 2 3 4 Markings on components 11 2 3 5 Compatible components 12 2 3 6 Technical data 12 2 4 Information for use 13 2 4 1 Corrosion 13 2 5 Optional accessories 13 3 Handling 15 3 1 Assembly infor...

Page 4: ...ing instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory t...

Page 5: ...ermany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant nat...

Page 6: ...tion operation and maintenance of potable water installations DIN EN 806 part 5 Planning execution operation and maintenance of potable water installations DIN EN 1717 Planning execution operation and...

Page 7: ...N 12828 Scope Notice Regulations applicable in Ger many Designation noise class I DIN EN 13828 Scope Notice Regulations applicable in Ger many Permitted pipe types DVGW Arbeitsblatt W 534 Permitted co...

Page 8: ...table water installations DIN EN 806 5 2 2 Intended use Coordinate the use of the model for areas of use and media other than those described with the Viega Service Center A ball valve is a fitting th...

Page 9: ...ons from section Media on page 6 n Heating water for pump hot water heating systems see Regula tions from section Media on page 6 n Compressed air in compliance with the specification of the sealing e...

Page 10: ...ons d 15 18 22 28 35 42 54 2 3 2 Press connection with SC Contur Fig 1 Press connection with a press connector as an example The press connection has a circumferential bead in which the sealing elemen...

Page 11: ...tory fitted with EPDM sealing elements Area of use Potable water Heating Compressed air Technical gases Use all pipeline sections Pump hot water heating system all pipeline sections all pipeline secti...

Page 12: ...s and Sanpress Inox system The press connections are tested and approved according to the appli cable regulations with the following pipe types n Copper pipes see Regulations from section Compatible c...

Page 13: ...licon bronze are suit able for all types of potable water The chloride concentration in the medium must not exceed a maximum value of 250 mg l This chloride is not a disinfectant but in fact pertains...

Page 14: ...Fig 4 Model 2275 92 Easytop T shaped actuating lever Fig 5 Model 2275 94 Easytop thermometer Fig 6 Model 2275 97 Easytop media marking Product information Easytop ball valve with SC Contur 14 from 21...

Page 15: ...other sealing ele ments is not permitted 3 1 2 Mounting instructions Do not remove the model from the packaging until immedi ately before use System components may in some cases become damaged through...

Page 16: ...toothed hacksaw n deburrer and coloured pen for marking n press machine with constant pressing force n Press jaw or press ring with corresponding hinged adapter jaw suit able for the pipe diameter an...

Page 17: ...s NOTICE Leaky press connections due to damaged material Press connections can become leaky due to damaged pipes or sealing elements Observe the following instructions to avoid damage to pipes and sea...

Page 18: ...s are to be mounted onto a pipe without an interval the pipe must not be too short If the pipe is not inserted up to the prescribed insertion depth in the press connector during pressing the connectio...

Page 19: ...or onto the pipe as far as it will go Mark the insertion depth Place the press jaw on the press machine and push the retaining bolt in until it clicks into place INFO Observe the press tool instructio...

Page 20: ...Perform leakage test should in acc with the general rules of engineering for non potable water installations Document the result 3 3 Maintenance NOTICE Inform your customer or the operator of the pot...

Page 21: ...Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Easytop ball valve with SC Contu...