background image

for concealed cistern 2H, concealed cistern 2L, concealed cis-
tern 2C, concealed cistern Standard 2S

Model

Year built:

8315.1

from  07/2007

en_INT

Flush plate Visign for Style 10

Instructions for Use

Summary of Contents for 8315.1

Page 1: ...for concealed cistern 2H concealed cistern 2L concealed cis tern 2C concealed cistern Standard 2S Model Year built 8315 1 from 07 2007 en_INT Flush plate Visign for Style 10 Instructions for Use ...

Page 2: ...Flush plate Visign for Style 10 2 from 20 ...

Page 3: ...2 2 1 Overview 7 2 2 2 Technical data 7 3 Handling 8 3 1 Assembly information 8 3 1 1 Required material and tools 8 3 2 Assembly 8 3 2 1 Prepare cistern 8 3 2 2 Mount flush actuation 14 3 2 3 Mounting the flush plate 17 3 3 Commissioning 19 3 3 1 Setting the flush 19 3 4 Error faults and remedy 19 3 5 Care and maintenance 19 3 5 1 Maintenance tips 19 3 6 Disposal 20 Table of contents Flush plate V...

Page 4: ... does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns against possible life threatening injury WA...

Page 5: ...nd or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The pertinent national laws stand ards regulations and guidelines as well as other technical guidelines have priority over German European guidelines in this manual The information is not binding for other ...

Page 6: ...n model 2L Ascertain which model is installed before mounting The following infor mation will help you to determine the model of the cistern installed Cistern 2H The revision shaft of this cistern is found at a height of approx 1 metre on the front Cistern 2L The revision shaft of this cistern is either found at a height of approx 75 cm on the front or on the top Suitable cisterns Product informat...

Page 7: ...olt 2 2 2 Technical data The product exhibits the following technical data The flush volume for the flushes are n Small flush volume approx 3 4 litres n Large flush volume approx 6 9 litres For the setting of the flush see Ä Chapter 3 3 1 Setting the flush on page 19 Flush volume Product information Flush plate Visign for Style 10 7 from 20 ...

Page 8: ...cutter 3 2 Assembly 3 2 1 Prepare cistern The following work stages and diagrams differ depending on the cistern being used The relevant steps are marked accordingly Requirements n The cistern is fitted into the front wall n The front wall is tiled Cut into shaft cover Remove shaft cover Tool Handling Flush plate Visign for Style 10 8 from 20 ...

Page 9: ... Cut the corners of the revision shaft vertically through to the wall surface Bend out and pull down the sides of the revision shaft The edge of the revisions shaft must be flush with the wall surface Remove cistern cover Remove and keep the threaded bolts from the cistern cover Keep cistern casing Handling Flush plate Visign for Style 10 9 from 20 ...

Page 10: ...of the mechanism INFO Only for assembly of the flush plate on the top of cistern 2L Press the bow backwards from the mounting of the mechanism Turn the mechanism s lock by 90 in an anti clockwise direction ð The mechanism is unlocked and can be removed Remove and keep mechanism Handling Flush plate Visign for Style 10 10 from 20 ...

Page 11: ...ush with the surface n Mechanism has been removed Close corner valve Loosen flexible hose on the filling valve SW 19 Open the corner valve for a few seconds to rinse the pipe Re close corner valve Flush pipelines cistern 2H Handling Flush plate Visign for Style 10 11 from 20 ...

Page 12: ... Open corner valve Requirements n The revision shaft is shortened in such a way that it is flush with the upper edge of the tiles n Mechanism has been removed Close corner valve Flush pipelines cistern 2L Handling Flush plate Visign for Style 10 12 from 20 ...

Page 13: ...n the filling valve SW 19 Open the corner valve for a few seconds to rinse the pipe Re close corner valve Connect the flexible hose onto the filling valve Open corner valve Handling Flush plate Visign for Style 10 13 from 20 ...

Page 14: ...a clockwise direction ð The mechanism is locked How to install the mechanism depends on whether the flush plate is to be fitted to the front or top of the cistern Vertical installation flush plate on the front of the cistern Horizontal installation flush plate on the top of the cis tern Mount mechanism cistern 2H Mount mechanism cistern 2L Handling Flush plate Visign for Style 10 14 from 20 ...

Page 15: ...ctly in the recesses in the cistern Turn the mechanism s lock by 90 in a clockwise direction ð The mechanism is locked Vertical installation flush plate on the front of the cistern Horizontal installation flush plate on the top of the cistern Handling Flush plate Visign for Style 10 15 from 20 ...

Page 16: ...doing so ensure that the tracks on the top and bottom edge of the mechanism are in the indentations in the revision shaft of the cistern Turn the mechanism s lock by 90 in a clockwise direction ð The mechanism is locked Handling Flush plate Visign for Style 10 16 from 20 ...

Page 17: ...nted Re mount cistern casing Insert the threaded bolts so deeply that the upper edge of the threaded bolt sticks out approx 20 mm behind the upper edge of the tiles Secure threaded bolts with a 90 turn Screw on basic panel 20 20 Handling Flush plate Visign for Style 10 17 from 20 ...

Page 18: ... the basic panel If necessary shorten the actuating rod on the thread with a cutting knife Set the lower actuating rod flush with the basic panel If necessary shorten the actuating rod on the thread with a cutting knife Insert support in the basic panel Handling Flush plate Visign for Style 10 18 from 20 ...

Page 19: ...er in cistern corner valve is closed Open corner valve WC flush runs through Dirty seal in filling valve Check seal replace if necessary Dirty seal in drain valve Check seal replace if necessary WC flush actuation does not work The mechanism is not connected to the bow Hang the mechanism in the bow 3 5 Care and maintenance 3 5 1 Maintenance tips Normal soap or a mild cleaning agent can be used for...

Page 20: ...ter after the prescribed exposure time There should be no residue on the components 3 6 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Flush plate Visign for Style 10 20 from 20 ...

Reviews: