Place and press the flush plate onto the basic panel.
3.3
Commissioning
3.3.1
Setting the flush
Set the flush volume on the drain valve of the cistern.
Small flush volume (above): approx. 3–4 litres
Large flush volume (below): approx. 6–9 litres
3.4
Error, faults and remedy
Error
Cause
Remedy
WC does not flush
Cistern is not yet completely full
Wait until the cistern is sufficiently
full
No water in cistern, corner valve is
closed
Open corner valve
WC flush runs through
Dirty seal in filling valve
Check seal, replace if necessary
Dirty seal in drain valve
Check seal, replace if necessary
WC flush actuation does not work
The mechanism is not connected
to the bow
Hang the mechanism in the bow
3.5
Care and maintenance
3.5.1
Maintenance tips
Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the flush plate. Under no circumstances
should scouring agent or scratching objects be used.
Handling
Flush plate Visign for Style 10