             VRDK1/CL TECHNICAL MANUAL 

 

VER1.0 

CABLE SIZE GUIDE 

 

AUDIO SYSTEM 

Connections from door panel to telephone. 

Connections 

50m  100m 200m 300m 400m 

0.25mm² 0.35mm²  0.5mm²  0.75mm²  1.0mm² 

0.25mm² 0.35mm²  0.5mm²  0.75mm²  1.0mm² 

0.25mm² 0.35mm²  0.5mm²  0.75mm²  1.0mm² 

0.25mm² 0.35mm²  0.5mm²  0.75mm²  1.0mm² 

0.25mm² 0.35mm²  0.5mm²  0.75mm²  1.0mm² 

When ever possible connection 1(Tx) should be twisted with connection 3(Gnd) and connection 2(Rx) should 
be twisted with connection 3(Gnd) as pairs. 
Maximum acceptable resistance for terminals  = 10

 

 

Connections for power supply output to door panel and lock release connections. These 
connections are shown heavily outlined on the wiring diagram. 

 50m 

100m 

Connections 

0.5mm² 0.75mm² 

The power supply should be located as close to the door panel as possible for best performance. 
Maximum acceptable resistance for above cables = 3

 

 

TESTING THE INSTALLATION

 

 

-  Check all the connections have been made correctly and then power up the system.  
-  Call the apartment. Check for call to the apartment, speech in both directions and lock 

release. 

-  If the volume of speech needs to be adjusted, this can be done by adjusting the presets 

on the rear of the amplifier at the door panel. 

 

PANEL CARE

 

 
The door panels are manufactured from either 12 Gauge 304 grade stainless steel or 
mirror finished brass. It is important that the facia is cleaned on regular occasions to 
prevent dirt build up and tarnishing of the metal. A general household metal polish can be 
used but care should be taken to follow the grain of the metal when polishing and also 
avoid any polish build up around the call button which may prevent the button from 
operating correctly. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for VRDK1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 0 VANDAL RESISTANT ONE BUTTON CODED ACCESS DOOR ENTRY KIT VRDK1 CL 25H CL...

Page 2: ...PAGE 2 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0...

Page 3: ...ock release by pressing a button on the telephone Additionally users can gain access using an access code The kit does not include the electric lock release A 12V AC release should be used with this k...

Page 4: ...his power supply TELEPHONE Art 3021 BLOCK DIAGRAM CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Neutral...

Page 5: ...gulations Install an appropriate fused spur or isolation switch to isolate the mains Isolate the mains before carrying out any maintenance work on the system All intercom and access control cables mus...

Page 6: ...uld be located as close to the door panel as possible for best performance Maximum acceptable resistance for above cables 3 TESTING THE INSTALLATION Check all the connections have been made correctly...

Page 7: ...PAGE 7 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 ACCESSORIES CONNECTION GUIDE 3021 3021...

Page 8: ...PAGE 8 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 WIRING DIAGRAM...

Page 9: ...the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a relay...

Page 10: ...rom the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s code...

Page 11: ...is should be there all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Reviews: