PAGE 4 of 12 

             VRDK1/CL TECHNICAL MANUAL 

 

VER1.0 

 
Speech volume adjustments are carried out at the door panel using a small trimmer driver.  
 
 
 
 
 
 
 

POWER SUPPLY 

 

Art.520M 

The power supply is the Art.520M. Outputs of 12Vdc (200mA), 8Vdc (300mA) and 13Vac 
(1A) are available. The dc outputs are designed to power the amplifier modules only and 
can not be used to power other devices such as lock releases etc. These items must be 
connected to the AC output of this power supply. 
 

 
 
 
 
 
 
 

 
 .

 

TELEPHONE 

 

Art.3021

 

 
 
 
 
 
 
 
 
 
 
 

 
 

BLOCK DIAGRAM 
 

 
 
 
 
 
 
 

CONNECTIONS 

Terminal  Function 

+12 

 

12Vdc output (200mA Max.) 

+8 

 

8Vdc output (300mA Max.) 

-  

0V 

(Ground) 

 13Vac 

(1A 

Max.) 

 

 

 

230 

 

Mains in (Live connection) 

 

Mains in (Neutral connection) 

The Smart line Art.3021 is a wall mountable AC buzzer phone and 
includes a lock release push button.  

CONNECTIONS:- 

 Function 

Transmit speech to the door panel 

Receive speech from the door panel 

3 0V 

Not used (Electronic call tone input) 

Lock trigger (Switched 0V) 

Call  line (13Vac input to trigger buzzer) 

 

 

Adjustment for 

speech volume level 

at the door station 

Adjustment for 

speech volume at the 

apartment 

 

Fuse 
compartment 

 

Summary of Contents for VRDK1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 0 VANDAL RESISTANT ONE BUTTON CODED ACCESS DOOR ENTRY KIT VRDK1 CL 25H CL...

Page 2: ...PAGE 2 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0...

Page 3: ...ock release by pressing a button on the telephone Additionally users can gain access using an access code The kit does not include the electric lock release A 12V AC release should be used with this k...

Page 4: ...his power supply TELEPHONE Art 3021 BLOCK DIAGRAM CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Neutral...

Page 5: ...gulations Install an appropriate fused spur or isolation switch to isolate the mains Isolate the mains before carrying out any maintenance work on the system All intercom and access control cables mus...

Page 6: ...uld be located as close to the door panel as possible for best performance Maximum acceptable resistance for above cables 3 TESTING THE INSTALLATION Check all the connections have been made correctly...

Page 7: ...PAGE 7 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 ACCESSORIES CONNECTION GUIDE 3021 3021...

Page 8: ...PAGE 8 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 WIRING DIAGRAM...

Page 9: ...the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a relay...

Page 10: ...rom the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s code...

Page 11: ...is should be there all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Reviews: