TROUBLE SHOOTING

 

 

SYMPTOM TEST 

No speech from the door panel to the 
telephone. 

Check terminal 2 on the amplifier for continuity to 
terminal 2 on the telephone. 

 

Before lifting the handset, check the voltage to 
terminal 2 of the amplifier is 8-12Vdc. Trace this 
voltage to terminal 2 to the telephone. 

 

Check the voltage drops to approx. 1Vdc after the 
handset is lifted. (If not try another telephone) 

 

If all else fails try another amplifier at the door station 

 

 

No speech from the telephone to the door 
panel. 

Check terminal 1 on the door panel amplifier for 
continuity back to terminal 1 on the telephone. 

 

Before lifting the handset, check the voltage to on 
terminal 1 of the amplifier is 8-12Vdc. Trace this 
voltage to terminal 1 to the telephone. 

 

Check the voltage drops to approx. 4Vdc after the 
handset is lifted. (If not try another telephone) 

 

If all else fails try another amplifier at the door station 

 

 

No speech in either direction 

Check the 315mA fuse in the power supply 

 

Check for 8-12Vdc across terminals 3 & 4 on the 
door panel amplifier. This should be there all the time 
and comes directly from the PSU. 

 

 

Lock will not operate from telephone 

Check terminal 5 on the telephone. This terminal 
shorts to terminal 3 of the telephone when pressed 
(Becomes 0V). 

 

Check terminal 5 of the telephone is connected 
correctly to terminal 10 of the keypad. Try touching a 
wire across terminal 10 & terminal 2 on the keypad 
to ensure the codelock is operating the relay. 

 

If a push to exit is also connected to terminal 10 of 
the codelock ensure it is not a normally closed switch 
or in short. 

 

 

Nothing happens when any call button is 
pressed 

Check the common of the buttons has 13Vac 
present at all times.  

 

When a call button is pressed you should be able to 
read 13Vac on terminals 3 & 6 of the telephone (6 of 
the telephone comes direct from the call button). If 
voltage is there then check/change the buzzer. 

 

 

Hum on the speech lines 

Ensure all intercom cables do not run close to higher 
voltage cables 

 

Try another amplifier at the door panel. 

 

 

Codelock not operating 

Check power on terminals 1 & 2 on the codelock is 
12V. If this voltage is lower it may not operate the 
relays correctly. 

 
 
 
 

Check the keys beep when pressed. This will not 
happen if the codelock is faulty or has the incorrect 
power connected to terminals 1 & 2 

 

Try re-programming the codelock 

Summary of Contents for VRDK1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 0 VANDAL RESISTANT ONE BUTTON CODED ACCESS DOOR ENTRY KIT VRDK1 CL 25H CL...

Page 2: ...PAGE 2 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0...

Page 3: ...ock release by pressing a button on the telephone Additionally users can gain access using an access code The kit does not include the electric lock release A 12V AC release should be used with this k...

Page 4: ...his power supply TELEPHONE Art 3021 BLOCK DIAGRAM CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Neutral...

Page 5: ...gulations Install an appropriate fused spur or isolation switch to isolate the mains Isolate the mains before carrying out any maintenance work on the system All intercom and access control cables mus...

Page 6: ...uld be located as close to the door panel as possible for best performance Maximum acceptable resistance for above cables 3 TESTING THE INSTALLATION Check all the connections have been made correctly...

Page 7: ...PAGE 7 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 ACCESSORIES CONNECTION GUIDE 3021 3021...

Page 8: ...PAGE 8 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 WIRING DIAGRAM...

Page 9: ...the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a relay...

Page 10: ...rom the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s code...

Page 11: ...is should be there all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Reviews: