             VRDK1/CL TECHNICAL MANUAL 

 

VER1.0 

INSTALLATION

 

 
The wiring diagram towards the back of this manual should be followed carefully. Heavy 
duty conductors on wiring diagrams are shown heavily outlined, These wires should be 
doubled up.  

 

-  Check that all components are free from damage before installing (Do not proceed with 

installation in the event of damage). 

 
-  Keep all packaging away from children. 
 
-  Do not obstruct the ventilation openings or slots on any of the devices. 
 
-  All connections to mains voltages must be made to the current national standards (IEE 

Wiring regulations) 

 
-  Install an appropriate fused spur or isolation switch to isolate the mains. 
 
 
-  Isolate the mains before carrying out any maintenance work on the system. 
 
-  All intercom and access control cables must be routed separately from the mains. 

 

L

ock release and AC buzzer back EMF protection : 

A capacitor must be fitted across 

the terminals on an AC lock release and the AC buzzer inside the telephone.

 

When using 

a DC lock release with a separate DC PSU a diode must be fitted across the terminals of 
the lock release as shown in the diagrams below to suppress back EMF voltages. 
 

  

LOCK RELEASE

12V AC

~ ~

0.1uF capacitor

              

+

-

1N4002

+

-

12V DC

LOCK RELEASE

DIODE

 

 
 
Safety Note : 

An earth connection should also be fitted to the door panel stainless steel 

facia using one of the studs provided. 
 
 
 
 

Summary of Contents for VRDK1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 0 VANDAL RESISTANT ONE BUTTON CODED ACCESS DOOR ENTRY KIT VRDK1 CL 25H CL...

Page 2: ...PAGE 2 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0...

Page 3: ...ock release by pressing a button on the telephone Additionally users can gain access using an access code The kit does not include the electric lock release A 12V AC release should be used with this k...

Page 4: ...his power supply TELEPHONE Art 3021 BLOCK DIAGRAM CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Neutral...

Page 5: ...gulations Install an appropriate fused spur or isolation switch to isolate the mains Isolate the mains before carrying out any maintenance work on the system All intercom and access control cables mus...

Page 6: ...uld be located as close to the door panel as possible for best performance Maximum acceptable resistance for above cables 3 TESTING THE INSTALLATION Check all the connections have been made correctly...

Page 7: ...PAGE 7 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 ACCESSORIES CONNECTION GUIDE 3021 3021...

Page 8: ...PAGE 8 of 12 VRDK1 CL TECHNICAL MANUAL VER1 0 WIRING DIAGRAM...

Page 9: ...the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a relay...

Page 10: ...rom the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s code...

Page 11: ...is should be there all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...