             VR4K-1/CL TECHNICAL MANUAL 

 

VER1.2 

Maximum acceptable resistance for above cables = 3

 

TESTING THE INSTALLATION

 

 

-  Check all the connections have been made correctly and dip-switches have been set 

and then power up the system.  

-  Call the apartments. Check for call to the apartment, speech in both directions and lock 

release and correct operation of the SPEAK & DOOR OPEN LED’s. 

-  If the volume of speech needs to be adjusted, this can be done by adjusting the presets 

on the rear of the amplifier at the door panel. 

-  Program a code into the codelock and check it releases the door for the programmed 

time. 

 

 

PANEL CARE

 

 
The door panel is manufactured from 12 Gauge 304 grade stainless steel. It is important 
that the facia is cleaned on regular occasions to prevent dirt build up and tarnishing of the 
metal. A general household metal polish can be used but care should be taken to follow 
the grain of the metal when polishing and also avoid any polish build up around the call 
button which may prevent the button from operating correctly. 
 

ACCESSORIES CONNECTION GUIDE 

 
 

512A Extension sounder  

 

 

       ES/1 Extension Strobe 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

o

  A normally open push to exit button can be connected across PTE & - on the door 

panel. 

o

  When triggering a gate, use C & NO as dry contacts. 

o

  When using a fail safe lock release use a separate DC PSU and the NC connection 

instead of the NO connection. 

o

  Remember to fit the 0.1uF capacitor across the lock release. 

 
 
 
 

Summary of Contents for VR4K-1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 2 VANDAL RESISTANT ONE BUTTON DOOR ENTRY KIT WITH CODED ACCESS VR4K 1 CL...

Page 2: ...PAGE 2 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2...

Page 3: ...h this kit The output for the lock is a dry contact relay so any other type of lock can be used with an appropriate PSU If this kit is to be used with a gate the dry contact output can be used to trig...

Page 4: ...n 0V side LED Not used with this kit BSY Busy signal for use with multiple door systems Normally high 12V Low when busy 0V SL Switched 0V output to switch on video PSU 0V throughout a call open collec...

Page 5: ...er supply or auxiliary power supply TELEPHONE Art 3111 CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Ne...

Page 6: ...cess control cables must be routed separately from the mains When the panel is mounted on an uneven surface use additional sealant to protect from water ingress LOCK RELEASE 12V AC 0 1uF capacitor CAB...

Page 7: ...L CARE The door panel is manufactured from 12 Gauge 304 grade stainless steel It is important that the facia is cleaned on regular occasions to prevent dirt build up and tarnishing of the metal A gene...

Page 8: ...PAGE 8 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2 WIRING DIAGRAM...

Page 9: ...follow the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a...

Page 10: ...from the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s cod...

Page 11: ...all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed Becomes 0V and send...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Reviews: