             VR4K-1/CL TECHNICAL MANUAL 

 

VER1.2 

 

BLOCK DIAGRAM 
 

 

 

INSTALLATION

 

 
The wiring diagram towards the back of this manual should be followed carefully. Heavy 
duty conductors on wiring diagrams are shown heavily outlined; these wires should be 
doubled up.  

 

Check that all components are free from damage before installing (Do not proceed with installation in the 
event of damage). 

Keep all packaging away from children. 

Do not obstruct the ventilation openings or slots on any of the devices. 

-  All connections to mains voltages must be made to the current national standards (IEE Wiring 

regulations) 

Install an appropriate fused spur or isolation switch to isolate the mains. 

Isolate the mains before carrying out any maintenance work on the system. 

All intercom and access control cables must be routed separately from the mains. 

When the panel is mounted on an uneven surface, use additional sealant to protect from water ingress. 

LOCK RELEASE

12V AC

~ ~

0.1uF capacitor

 

 

CABLE SIZE GUIDE 

 

Connections from door panel to telephone. 

Connections 

50m  100m 200m 300m 400m 

0.25mm² 0.35mm²  0.5mm² 0.75mm² 1.0mm² 

0.25mm² 0.35mm²  0.5mm² 0.75mm² 1.0mm² 

0.25mm² 0.35mm²  0.5mm² 0.75mm² 1.0mm² 

0.25mm² 0.35mm²  0.5mm² 0.75mm² 1.0mm² 

0.25mm² 0.35mm²  0.5mm² 0.75mm² 1.0mm² 

Maximum acceptable resistance for all terminals = 10

 

 

Connections for power supply output to door panel and lock release connections. These 
connections are shown heavily outlined on the wiring diagram. 

 50m 

100m 

Connections 

0.5mm² 0.75mm² 

The power supply should be located as close to the door panel as possible for best performance. 

L

ock release back EMF protection : 

capacitor should be fitted across the terminals on 
an AC lock release

 

as shown in the diagram 

below to suppress back EMF voltages. 

Summary of Contents for VR4K-1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 2 VANDAL RESISTANT ONE BUTTON DOOR ENTRY KIT WITH CODED ACCESS VR4K 1 CL...

Page 2: ...PAGE 2 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2...

Page 3: ...h this kit The output for the lock is a dry contact relay so any other type of lock can be used with an appropriate PSU If this kit is to be used with a gate the dry contact output can be used to trig...

Page 4: ...n 0V side LED Not used with this kit BSY Busy signal for use with multiple door systems Normally high 12V Low when busy 0V SL Switched 0V output to switch on video PSU 0V throughout a call open collec...

Page 5: ...er supply or auxiliary power supply TELEPHONE Art 3111 CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Ne...

Page 6: ...cess control cables must be routed separately from the mains When the panel is mounted on an uneven surface use additional sealant to protect from water ingress LOCK RELEASE 12V AC 0 1uF capacitor CAB...

Page 7: ...L CARE The door panel is manufactured from 12 Gauge 304 grade stainless steel It is important that the facia is cleaned on regular occasions to prevent dirt build up and tarnishing of the metal A gene...

Page 8: ...PAGE 8 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2 WIRING DIAGRAM...

Page 9: ...follow the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a...

Page 10: ...from the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s cod...

Page 11: ...all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed Becomes 0V and send...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Reviews: