Jumper 

Jumper JP controls the reassurance tone volume level at the door panel. 
 
 
 
 
 

POTS 

Speech volume adjustments are carried out at the door panel using a small trimmer driver.  
 
 
 
 
 
 

 
Amplifier module (VX136) 

 

 

Connection Function 

Receive speech from apartment 

Transmit speech to apartment 

+ +12Vdc 

input 

- 0V 

(Ground) 

Switched 0V from phone to trigger door release relay 

Electronic call tone output to common side of call buttons 

0V for use with push to exit input (PTE) 

PTE 

Switched 0V input from push to exit button to trigger door release relay 

Common connection of dry contact relay 

NC 

Normally closed connection of dry contact relay 

NO 

Normally open connection of dry contact relay 

D+ 

External link to door open (+12V side) LED. Not used with this kit 

D- 

External link to door open (0V side) LED. Not used with this kit 

BSY 

Busy signal for use with multiple door systems (Normally high, 12V. Low when busy 0V) 

SL 

Switched 0V output to switch on video PSU. (0V throughout a call, open collector in standby) 

F1 

Switched 0V output to switch on camera. (0V throughout a call, open collector in standby) 

 

Codelock module (Art.VR4KCLM-1) 

 

 

Connection Function 

12-24V ac/dc power input 

0V power input 

C1 

Common connection of relay 1 (Dry contact) 

NO1 

Normally open connection of relay 1 (Dry contact) 

NC1 

Normally closed connection of relay 1 (Dry contact) 

C2 

Common connection of relay 2 (Dry contact) 

NO2 

Normally open connection of relay 2 (Dry contact) 

NC2 

Normally closed connection of relay 2 (Dry contact) 

SW1 

Push to exit input for relay 1 (Triggered by 0V) 

SW2 

Push to exit input for relay 2 (Triggered by 0V) 

 
 
 
 

Adjustment for 

speech volume level 

at the door station 

Adjustment for 

speech volume at the 

apartment 

Position H 

High volume reassurance tones 

Position L 

Low Volume reassurance tones 

No Jumper 

No reassurance tones 

Summary of Contents for VR4K-1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 2 VANDAL RESISTANT ONE BUTTON DOOR ENTRY KIT WITH CODED ACCESS VR4K 1 CL...

Page 2: ...PAGE 2 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2...

Page 3: ...h this kit The output for the lock is a dry contact relay so any other type of lock can be used with an appropriate PSU If this kit is to be used with a gate the dry contact output can be used to trig...

Page 4: ...n 0V side LED Not used with this kit BSY Busy signal for use with multiple door systems Normally high 12V Low when busy 0V SL Switched 0V output to switch on video PSU 0V throughout a call open collec...

Page 5: ...er supply or auxiliary power supply TELEPHONE Art 3111 CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Ne...

Page 6: ...cess control cables must be routed separately from the mains When the panel is mounted on an uneven surface use additional sealant to protect from water ingress LOCK RELEASE 12V AC 0 1uF capacitor CAB...

Page 7: ...L CARE The door panel is manufactured from 12 Gauge 304 grade stainless steel It is important that the facia is cleaned on regular occasions to prevent dirt build up and tarnishing of the metal A gene...

Page 8: ...PAGE 8 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2 WIRING DIAGRAM...

Page 9: ...follow the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a...

Page 10: ...from the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s cod...

Page 11: ...all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed Becomes 0V and send...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Reviews: