PAGE 5 of 12
VR4K-1/CL TECHNICAL MANUAL
VER1.2
Dimensions
PANEL
FLUSH BACK BOX
Surface Audio panel with codelock
135mm(W) x 280mm(H) x 43mm(D)
NA
Flush Audio panel with codelock
135mm(W) x 280mm(H) x 16mm(D)
120mm(W) x 263mm(H) x 30mm(D)
POWER SUPPLY
Art.520M
The power supply is the Art.520M. Outputs of 12Vdc (200mA), 8Vdc (300mA) and 13Vac
(1A) are available. The dc outputs are designed to power the amplifier modules only and
must not be used to power other devices such as lock releases etc. These items must be
connected to the AC output of this power supply or auxiliary power supply.
.
TELEPHONE
Art.3111
CONNECTIONS
Terminal Function
+12
12Vdc output (200mA Max.)
+8
8Vdc output (300mA Max.)
-
0V
(Ground)
~
13Vac
(1A
Max.)
230
Mains in (Live connection)
0
Mains in (Neutral connection)
The Art.3111 is a white ABS plastic wall mounting electronic call
telephone and includes a lock release push button and spare dry
contact button. There is a three position call volume control external
to the top left side of the telephone.
CONNECTIONS:-
Function
1
Transmit speech to the door panel
2
Receive speech from the door panel
3 0V
4
Call tone input
5
Lock trigger (Switched 0V)
6 Not
used
8
One side of spare dry contact button (Max. 200mA 24V)
9
Second side of spare dry contact button (Max. 200mA 24V)
Fuse
compartment
5