background image

 
 
 

PAGE 5 of 12 

             VR4K-1/CL TECHNICAL MANUAL 

 

VER1.2 

 

Dimensions 

 

PANEL 

FLUSH BACK BOX 

Surface Audio panel with codelock 

135mm(W) x 280mm(H) x 43mm(D) 

NA 

Flush Audio panel with codelock 

135mm(W) x 280mm(H) x 16mm(D) 

120mm(W) x 263mm(H) x 30mm(D) 

 
 

POWER SUPPLY 

 

Art.520M 

The power supply is the Art.520M. Outputs of 12Vdc (200mA), 8Vdc (300mA) and 13Vac 
(1A) are available. The dc outputs are designed to power the amplifier modules only and 
must not be used to power other devices such as lock releases etc. These items must be 
connected to the AC output of this power supply or auxiliary power supply. 
 

 
 
 
 
 
 
 

 

 

TELEPHONE 

 

Art.3111

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CONNECTIONS 

Terminal  Function 

+12 

 

12Vdc output (200mA Max.) 

+8 

 

8Vdc output (300mA Max.) 

-  

0V 

(Ground) 

 13Vac 

(1A 

Max.) 

 

 

 

230 

 

Mains in (Live connection) 

 

Mains in (Neutral connection) 

The Art.3111 is a white ABS plastic wall mounting electronic call 
telephone and includes a lock release push button and spare dry 
contact button. There is a three position call volume control external 
to the top left side of the telephone. 
 

CONNECTIONS:- 
 Function 

Transmit speech to the door panel 

Receive speech from the door panel 

3 0V 

Call tone input 

Lock trigger (Switched 0V) 

6 Not 

used 

One side of spare dry contact button (Max. 200mA 24V) 

Second side of spare dry contact button (Max. 200mA 24V) 

 

Fuse 
compartment 

 

5

Summary of Contents for VR4K-1/CL

Page 1: ...TECHNICAL MANUAL EDITION 1 2 VANDAL RESISTANT ONE BUTTON DOOR ENTRY KIT WITH CODED ACCESS VR4K 1 CL...

Page 2: ...PAGE 2 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2...

Page 3: ...h this kit The output for the lock is a dry contact relay so any other type of lock can be used with an appropriate PSU If this kit is to be used with a gate the dry contact output can be used to trig...

Page 4: ...n 0V side LED Not used with this kit BSY Busy signal for use with multiple door systems Normally high 12V Low when busy 0V SL Switched 0V output to switch on video PSU 0V throughout a call open collec...

Page 5: ...er supply or auxiliary power supply TELEPHONE Art 3111 CONNECTIONS Terminal Function 12 12Vdc output 200mA Max 8 8Vdc output 300mA Max 0V Ground 13Vac 1A Max 230 Mains in Live connection 0 Mains in Ne...

Page 6: ...cess control cables must be routed separately from the mains When the panel is mounted on an uneven surface use additional sealant to protect from water ingress LOCK RELEASE 12V AC 0 1uF capacitor CAB...

Page 7: ...L CARE The door panel is manufactured from 12 Gauge 304 grade stainless steel It is important that the facia is cleaned on regular occasions to prevent dirt build up and tarnishing of the metal A gene...

Page 8: ...PAGE 8 of 12 VR4K 1 CL TECHNICAL MANUAL VER1 2 WIRING DIAGRAM...

Page 9: ...follow the factory default procedure on the following page Enter a new engineers code or enter the same engineers code again followed by enter This code can be from 4 8 digits and will not activate a...

Page 10: ...from the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s cod...

Page 11: ...all the time and comes directly from the PSU Lock will not operate from telephone Check terminal 5 on the telephone This terminal shorts to terminal 3 of the telephone when pressed Becomes 0V and send...

Page 12: ...Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech v...

Reviews: