background image

ENUK - V1.0 - 08/06/18 

- 8 -

Art. KR-AV-VR - Installation Instructions

Kristallo Series

ADDITIONAL BACK BOX INSTALLATION NOTES
REMOVING THE BACK BOX KNOCKOUTS

Due care should be taken when removing the knockout(s) on the base of the back box to avoid personal injury. Where necessary use 

the appropriate tools and wear the appropriate protective clothing (gloves, eye protection etc.) when removing the knockouts. 
1.  Before embeding the flush box into the wall or mounting the surface box to the wall it is advised to first remove the knockout(s) 

required;

2.  Take a flat-head screwdriver and use the flat end to gently ‘tap out’ and apply pressure to the knockout fixing, see 

Fig.17

 and 

Fig.18

;

3.  Once the knockout fixing has been removed, 

Fig.19

, push down on the knockout, see 

Fig.20

;

4.  Using a set of pliers grip the end of the knockout and ease it back and forth, 

Fig.21

, until the other knockout fixing fatigues and the 

knockout breaks away from the base of the back box. If necessary file down and smooth out any rough edges with a metal file;

5.  Fit a 

Ø20mm

 rubber grommet into the knockout hole, see 

Fig.22

.

knockout fixings

knockout cover

flat-head screwdriver

‘tap out’ knockout fixing

knockout

fixing

removed

Fig. 17

 

Fig. 18

 

Fig. 19

 

push down on the knockout

ease the knockout

back and forth to

remove

fit a Ø20mm

rubber 

grommet

to the 

knockout hole

Fig. 20

 

Fig. 21

 

Fig. 22

 

EMBEDING AND FIXING THE BACK BOX TO THE WALL

The flush box and surface back box need to be embeded or fixed to the wall respectively, 

therefore a suitable set of masonry screws and wall plugs should be used to do this. It 

is recommended that 4x 

40mm, Ø3.5mm

 self-tapping masonry screws with 4x 

40mm, 

Ø4mm

 nylon type wall plugs are used, see 

Fig.23

.

Where necessary use the appropriate power tools and wear the appropriate protective 

clothing (gloves, eye protection etc.) when drilling the fixing holes to mount the box 

and cutting out the hole in the wall to embed the flush box.

USING SILICON

Whenever using silicon sealant remember to wash your hands after use and always 

discard of any excess silicon waste responsibly.

SOLID WALL

Base of back box 

40mm, Ø4mm wall 

plug embeded into 

the wall 

40mm, Ø3.5mm 

self-tapping masonry 

screw 

Fig. 23

 

Art. KR-AV-VR 

 Vandal Resistant Digital A/V Door Panel for VX2200

Summary of Contents for Kristallo KR-AV-VR

Page 1: ...8 1 to 8 are used to set the address of the videophone to call the ninth is used to set the door opening time 2 seconds OFF 6 seconds ON The tenth is not used Loudspeaker and microphone volume adjust...

Page 2: ...h bank see Fig 2 to set the PHONE ID for the local videophone Each switch corresponds to one bit which can have a value of 0 OFF or 1 ON Each bit corresponds to a decimal weight depending on the posit...

Page 3: ...2 O Video signal V2 output towards the local videophone V1 I Video signal V1 input from the main intercom door station V2 I Video signal V2 input from the main intercom door station L O Data BUS out t...

Page 4: ...used where appropriate IMPORTANT NOTE Only bare copper BC cable should be used solid or stranded is acceptable Please be aware that when selecting a cable the following should NOT be used Copper Coate...

Page 5: ...e M4 flat washer followed by the M4 spring washer over the earth stud on the front plate Next place the eyelet of one end of the earth strap on top of the M4 spring washer Finally fit the M4 nut on to...

Page 6: ...between the wall and the flush box ON THE LEFT TOP AND RIGHT SIDES ONLY AND ENSURE ALLTHE CABLE ENTRY HOLES ARE SEALED DON T USE SILICON SEALANT ON THE BOTTOM SIDE OF THE BACK BOX Fig 9 3 Embed the f...

Page 7: ...rill the 4 fixing holes insert the wall plugs and feed the cables through the surface box knockout required Fix the surface box to the wall using self tapping masonry screws see Fig 14 remember to all...

Page 8: ...metal file 5 Fit a 20mm rubber grommet into the knockout hole see Fig 22 knockout fixings knockout cover flat head screwdriver tap out knockout fixing knockout fixing removed Fig 17 Fig 18 Fig 19 pus...

Page 9: ...ddress N 1 Art KRV78 SE 12Vac Gnd L L V1V2 REL LGT V1 O V2 O V1 I V2 I L O L I Gnd 12V NC2 4 C01 NC1 NO1 CO2 1 2 3 Art 506N NO2 5 Art 6272 Address N 2 Art 6272 SE 12Vac KR AV VR Panel Address ID 2 KR...

Page 10: ...1 2 3 4 5 6 7 8 ON 61 1 2 3 4 5 6 7 8 ON 62 1 2 3 4 5 6 7 8 ON 63 1 2 3 4 5 6 7 8 ON 64 1 2 3 4 5 6 7 8 ON 65 1 2 3 4 5 6 7 8 ON 66 1 2 3 4 5 6 7 8 ON 67 1 2 3 4 5 6 7 8 ON 68 1 2 3 4 5 6 7 8 ON 69 1...

Page 11: ...87 1 2 3 4 5 6 7 8 ON 188 1 2 3 4 5 6 7 8 ON 189 1 2 3 4 5 6 7 8 ON 190 1 2 3 4 5 6 7 8 ON 191 1 2 3 4 5 6 7 8 ON 192 1 2 3 4 5 6 7 8 ON 193 1 2 3 4 5 6 7 8 ON 194 1 2 3 4 5 6 7 8 ON 195 1 2 3 4 5 6 7...

Page 12: ...uropee 2014 30 UE EMC 2014 35 UE LVD 2011 65 UE RoHS marcatura CE 93 68 EEC MANUFACTURER FABBRICANTE FABRICANT FABRICANTE FABRIKANT VIDEX ELECTRONICS S P A Via del Lavoro 1 63846 Monte Giberto FM Ital...

Reviews: