background image

ENUK - V1.0 - 08/06/18 

- 5 -

Kristallo Series

Art. KR-AV-VR - Installation Instructions

ELECTRIC LOCK AND VOLT FREE CONNECTIONS

An electric lock (fail safe or fail secure) cannot be connected directly to the 

KR-AV

 unit. The “

REL

” output can be connected to a 

remote relay (

Art.506N

) which can then be connected directly to the lock. An additional 12Vac or dc power supply (depending on 

the type of lock fitted) may also be required. Follow 

Fig.4

 for fail secure lock release wiring and 

Fig.5

 for fail safe lock release wiring.

If volt free wiring is required, 

e.g.

 volt free connections to a set of gate or barrier controls, then simply follow 

Fig.4

 but omit the lock 

wiring and instead connect the 

CO

/

NO

 relay terminals directly into the appropriate trigger input on the gate or barrier controls.

KR-AV-VR

Terminals

Art.506N

GND

+12V

dc

GND

+12V

ac/dc

12Vac/dc

FAIL SECURE

LOCK RELEASE

VOLT

FREE

KR-AV-VR

Terminals

Art.506N

GND

+12V

dc

GND

+12V

ac/dc

12Vdc

FAIL SAFE

LOCK RELEASE

Fig. 4

 

Fig. 5

 

EARTHING THE FRONT PANEL TO THE BACK BOX

It is important to earth the 

KR-AV-VR

 panel’s front plate to the 

back box with the appropriate fixings and earth strap provided. 

Refer to 

Fig.6

 and follow the steps below:

•  First place the M4 flat washer followed by the M4 spring 

washer over the earth stud on the front plate;

•  Next place the eyelet of one end of the earth strap on top 

of the M4 spring washer;

•  Finally fit the M4 nut on top of the earth strap eyelet and 

tighten firmly into place;

•  Repeat the steps above when fitting the other end of the 

earth strap to the earth stud inside the back box.

top

view

VR plate

M4 washer

M4 spring 

washer

M4 nut

earth stud

earth strap

Fig. 6

 

•  The earth stud connection inside the back box should then be connected in the same way to the building’s earth connection.

PANEL CARE AND MAINTENANCE

As the panel is manufactured from 12 gauge brushed stainless steel it is important that the VR plate is cleaned on a regular basis 

to prevent dirt build up and tarnishing. A clean and soft cloth can be used with moderate warm water or non-aggressive cleansers. 

Additional care should be taken to follow the grain of the metal when polishing and always only polish in one direction to avoid 

light scratching of the plate. Also try to avoid any polish build up around the panel’s button which may prevent the button from 

operating correctly.

DO NOT USE ANY OF THE FOLLOWING:

•  Abrasive liquids;
•  Chlorine-based liquids;
•  Metal cleaning products (including Sidol stainless steel cleaner as this can affect the engraving);
•  Hydrochloride bleaches.

Art. KR-AV-VR 

 Vandal Resistant Digital A/V Door Panel for VX2200

Summary of Contents for Kristallo KR-AV-VR

Page 1: ...8 1 to 8 are used to set the address of the videophone to call the ninth is used to set the door opening time 2 seconds OFF 6 seconds ON The tenth is not used Loudspeaker and microphone volume adjust...

Page 2: ...h bank see Fig 2 to set the PHONE ID for the local videophone Each switch corresponds to one bit which can have a value of 0 OFF or 1 ON Each bit corresponds to a decimal weight depending on the posit...

Page 3: ...2 O Video signal V2 output towards the local videophone V1 I Video signal V1 input from the main intercom door station V2 I Video signal V2 input from the main intercom door station L O Data BUS out t...

Page 4: ...used where appropriate IMPORTANT NOTE Only bare copper BC cable should be used solid or stranded is acceptable Please be aware that when selecting a cable the following should NOT be used Copper Coate...

Page 5: ...e M4 flat washer followed by the M4 spring washer over the earth stud on the front plate Next place the eyelet of one end of the earth strap on top of the M4 spring washer Finally fit the M4 nut on to...

Page 6: ...between the wall and the flush box ON THE LEFT TOP AND RIGHT SIDES ONLY AND ENSURE ALLTHE CABLE ENTRY HOLES ARE SEALED DON T USE SILICON SEALANT ON THE BOTTOM SIDE OF THE BACK BOX Fig 9 3 Embed the f...

Page 7: ...rill the 4 fixing holes insert the wall plugs and feed the cables through the surface box knockout required Fix the surface box to the wall using self tapping masonry screws see Fig 14 remember to all...

Page 8: ...metal file 5 Fit a 20mm rubber grommet into the knockout hole see Fig 22 knockout fixings knockout cover flat head screwdriver tap out knockout fixing knockout fixing removed Fig 17 Fig 18 Fig 19 pus...

Page 9: ...ddress N 1 Art KRV78 SE 12Vac Gnd L L V1V2 REL LGT V1 O V2 O V1 I V2 I L O L I Gnd 12V NC2 4 C01 NC1 NO1 CO2 1 2 3 Art 506N NO2 5 Art 6272 Address N 2 Art 6272 SE 12Vac KR AV VR Panel Address ID 2 KR...

Page 10: ...1 2 3 4 5 6 7 8 ON 61 1 2 3 4 5 6 7 8 ON 62 1 2 3 4 5 6 7 8 ON 63 1 2 3 4 5 6 7 8 ON 64 1 2 3 4 5 6 7 8 ON 65 1 2 3 4 5 6 7 8 ON 66 1 2 3 4 5 6 7 8 ON 67 1 2 3 4 5 6 7 8 ON 68 1 2 3 4 5 6 7 8 ON 69 1...

Page 11: ...87 1 2 3 4 5 6 7 8 ON 188 1 2 3 4 5 6 7 8 ON 189 1 2 3 4 5 6 7 8 ON 190 1 2 3 4 5 6 7 8 ON 191 1 2 3 4 5 6 7 8 ON 192 1 2 3 4 5 6 7 8 ON 193 1 2 3 4 5 6 7 8 ON 194 1 2 3 4 5 6 7 8 ON 195 1 2 3 4 5 6 7...

Page 12: ...uropee 2014 30 UE EMC 2014 35 UE LVD 2011 65 UE RoHS marcatura CE 93 68 EEC MANUFACTURER FABBRICANTE FABRICANT FABRICANTE FABRIKANT VIDEX ELECTRONICS S P A Via del Lavoro 1 63846 Monte Giberto FM Ital...