TERMINALS

REL

Open collector active low output Vdc 100mA max enabled by lock release button on videophone

LGT

Terminal not used

V1-O

Video signal V1 output towards the local videophone

V2-O

Video signal V2 output towards the local videophone

V1-I

Video signal V1 input from the main intercom door station

V2-I

Video signal V2 input from the main intercom door station

L-O

Data BUS out towards the local videophone

L-I

Data BUS in from the main intercom door station

Gnd

12Vdc power supply ground and Data BUS -(negative) connection

12V

12Vdc power supply input

TECHNICAL SPECIFICATION
Power supply voltage:

 12÷14Vdc

Power consumption:

 

Stand-by:  6mA max (on 12Vdc)

 

Operating:  200mA Max (on 12Vdc)

Working temperature:

  -10° +50° C

Summary of Contents for Kristallo KR-AV-VR

Page 1: ...8 1 to 8 are used to set the address of the videophone to call the ninth is used to set the door opening time 2 seconds OFF 6 seconds ON The tenth is not used Loudspeaker and microphone volume adjust...

Page 2: ...h bank see Fig 2 to set the PHONE ID for the local videophone Each switch corresponds to one bit which can have a value of 0 OFF or 1 ON Each bit corresponds to a decimal weight depending on the posit...

Page 3: ...2 O Video signal V2 output towards the local videophone V1 I Video signal V1 input from the main intercom door station V2 I Video signal V2 input from the main intercom door station L O Data BUS out t...

Page 4: ...used where appropriate IMPORTANT NOTE Only bare copper BC cable should be used solid or stranded is acceptable Please be aware that when selecting a cable the following should NOT be used Copper Coate...

Page 5: ...e M4 flat washer followed by the M4 spring washer over the earth stud on the front plate Next place the eyelet of one end of the earth strap on top of the M4 spring washer Finally fit the M4 nut on to...

Page 6: ...between the wall and the flush box ON THE LEFT TOP AND RIGHT SIDES ONLY AND ENSURE ALLTHE CABLE ENTRY HOLES ARE SEALED DON T USE SILICON SEALANT ON THE BOTTOM SIDE OF THE BACK BOX Fig 9 3 Embed the f...

Page 7: ...rill the 4 fixing holes insert the wall plugs and feed the cables through the surface box knockout required Fix the surface box to the wall using self tapping masonry screws see Fig 14 remember to all...

Page 8: ...metal file 5 Fit a 20mm rubber grommet into the knockout hole see Fig 22 knockout fixings knockout cover flat head screwdriver tap out knockout fixing knockout fixing removed Fig 17 Fig 18 Fig 19 pus...

Page 9: ...ddress N 1 Art KRV78 SE 12Vac Gnd L L V1V2 REL LGT V1 O V2 O V1 I V2 I L O L I Gnd 12V NC2 4 C01 NC1 NO1 CO2 1 2 3 Art 506N NO2 5 Art 6272 Address N 2 Art 6272 SE 12Vac KR AV VR Panel Address ID 2 KR...

Page 10: ...1 2 3 4 5 6 7 8 ON 61 1 2 3 4 5 6 7 8 ON 62 1 2 3 4 5 6 7 8 ON 63 1 2 3 4 5 6 7 8 ON 64 1 2 3 4 5 6 7 8 ON 65 1 2 3 4 5 6 7 8 ON 66 1 2 3 4 5 6 7 8 ON 67 1 2 3 4 5 6 7 8 ON 68 1 2 3 4 5 6 7 8 ON 69 1...

Page 11: ...87 1 2 3 4 5 6 7 8 ON 188 1 2 3 4 5 6 7 8 ON 189 1 2 3 4 5 6 7 8 ON 190 1 2 3 4 5 6 7 8 ON 191 1 2 3 4 5 6 7 8 ON 192 1 2 3 4 5 6 7 8 ON 193 1 2 3 4 5 6 7 8 ON 194 1 2 3 4 5 6 7 8 ON 195 1 2 3 4 5 6 7...

Page 12: ...uropee 2014 30 UE EMC 2014 35 UE LVD 2011 65 UE RoHS marcatura CE 93 68 EEC MANUFACTURER FABBRICANTE FABRICANT FABRICANTE FABRIKANT VIDEX ELECTRONICS S P A Via del Lavoro 1 63846 Monte Giberto FM Ital...