66250675-EN - V1.0 - 05/09/17
48
4000 Series Vandal Resistant GSM - Technical Manual
4000 Series Vandal Resistant GSM Audio Intercom with Proximity Facility
Programming the GSM Intercom
SHUTDOWN AND RESTART (RBT)
This command feature allows the GSM intercom to be remotely shutdown and then rebooted again. The following command can
be sent to the GSM module.
1111RBT
Shutdown and restart the GSM module.
IMPORTANT NOTE: This feature should not be confused with the ‘hard-wired’ reset (described on page 33). The RBT function
simply powers down the GSM module and then powers it back up again.
The following commands are reserved for the technical department for interrorgating the GSM module when testing and applying
specific additional features that are not covered in this technical manual. For the application of these commands please contact
Videx Technical on tel:
0191 224 3174
. For overseas customers please contact Videx customer support on tel:
(+39) 0734 631 699
.
PROGRAM BY ‘AT’ COMMANDS (PRG)
This is an advanced feature of the system which can allow an ‘AT’ format command to be sent to the OEM GSM module.
1111PRG(command)
Send an ‘AT’ command to the OEM module.
AT COMMAND SEND AT START UP (AT1, AT2 AND AT3)
The AT commands
AT1
,
AT2
and
AT3
are advanced commands of the GSM intercom that allows additional features to be incorprated
into the module for testing purposes and include additional features for a specific application that is not already covered in this
manual. The following commands can be sent to the GSM module.
1111AT1”ATxxxxxx”?
Include any AT command for AT1.
1111AT2”ATxxxxxx”?
Include any AT command for AT2.
1111AT3”ATxxxxxx”?
Include any AT command for AT3.