Introduction 

 
The Art380 is a self contained telephone interface module for use on an analogue telephone 
line. Its primary function is to enable a user to communicate with a telephone line and a door 
entry point (or points) from the same telephone handset. This handset can be a standard 
corded model, a cordless such as a DECT telephone or even a hands free telephone. The 
Art380’s main features are listed below:- 
 

o

  Communicate with both a telephone line and door entry points. 

o

  Open a door using the telephone keypad. 

o

  Open the speech to a door entry point without first being called. 

o

  Activate up to two auxiliary outputs. (Outputs can be either momentary or latching). 

o

  Reverse the door open relay for use with power to lock releases. 

o

  Make the following call adjustments in programming mode:- 

  Number of rings (From 1 – 10 rings) 

  Door open time (From 1 – 18 seconds) 

  Door open key (Either 0(default), 8 or 9) 

  Internal/external speech volume. 

o

  Divert the call to another pre-programmed number.

 or is engaged).

 

o

  Program an access code to protect the programming and the use of facilities in either 

divert mode or normal mode. 

o

  Operate in a hands free mode (Speech automatically adjusts the gain to the direction 

of speech). 

o

  One way speech mode (Simplex speech) 

o

  PABX mode (Allows the units to operate without the need for a telephone line). 

o

  Dial in facility which allows the Art380 to be activated from an incoming telephone call. 

 

Mounting instructions

 

 
The Art380 can be either mounted to a DIN rail or mounted directly to a wall. Begin by 
removing the terminal side covers by unscrewing the retaining screws. Either clip the Art380 
to a DIN rail or screw directly to the wall using two screws and suitable wall plugs. You should 
leave the terminal side covers off until all connections have been made.  
 

Safety notes 

 
The system must be installed by a competent installer following the regulations in force. We 
recommend:- 
 

  Use an appropriate fused spur to isolate the mains from the Art380. 

  Isolate the mains before removing any covers from the system (Please note: There are no 

user serviceable parts within the Art380 and so the covers should only be removed by a 
competent technician). 

 

Connections to the telephone line

  

 
Each telephone line coming into your home or office must be fitted with a six pin primary 
socket installed by the PTO (Public Telecommunication Operator). It is illegal to tamper in any 
way with this primary socket and you can’t install it yourself. Additional connections to the 
primary socket must be carried out using a BT style plug (You cannot connect directly to the 

Summary of Contents for ART380

Page 1: ...1 of 19 ART380 TELEPHONE INTERFACE MANUAL Installation and programming manual Version 1 6 07 2009...

Page 2: ...0 Setting the auxiliary outputs 10 Advanced speech setup options 11 Dial in facility setup 11 Divert call setup 12 Access code setup 13 Specialised setup 13 User commands 14 Approval 14 Troubleshootin...

Page 3: ...o the direction of speech o One way speech mode Simplex speech o PABX mode Allows the units to operate without the need for a telephone line o Dial in facility which allows the Art380 to be activated...

Page 4: ...ed open each one and check it is a secondary socket and not another master A secondary socket will not contain any components whereas a master socket will have a capacitor resistor and suppressor fitt...

Page 5: ...open relay Dry contact Continuity checks can be made between C NO NO Normally open or normally closed connection of door open relay depending on programmed state Dry contact Continuity checks can be m...

Page 6: ...lephones are required They should be connected to the Art380 via a REN booster The REN booster is a third party product not supplied by Videx IMPORTANT NOTE When using a REN boost the Art 380 must be...

Page 7: ...ot exceed 100M Jumper settings There are four jumpers on the Art380 labelled S1 S2 S3 and S4 Jumpers S1 S2 are used to setup the telephone ringing frequency as either 50Hz or 25Hz Jumpers S3 S4 are fo...

Page 8: ...programming NOTE If the access code is enabled this should be entered after the For example to reverse the relay when a code of 1234 is setup enter 1234 10 1 Description Code Variant X Default X Relay...

Page 9: ...ode Divert phone numbers 32 1 n n Telephone number Example program the number as 0123 456789 would be 32 1 0123456789 and to program the second as NOTE Always confirm the number using the key N A Reve...

Page 10: ...djust the number of rings The Art380 can be programmed to ring the telephone s for as little as 1 ring or for a maximum of 10 rings using one of the following codes Code Rings Code Rings Code 21 1 1 C...

Page 11: ...volume in both directions electronically Dial in facility setup The dial in facility can be used to allow a caller from a telephone line to dial into the Art380 and access the functions available This...

Page 12: ...l automatically after a preset number of seconds When this mode is enabled the telephone in the house will ring for the number of seconds programmed and if after this period the call still has not bee...

Page 13: ...ivated Note It is also possible to put the Art380 into PABX mode by following these steps 1 Switch the mains off to the Art380 2 Short terminals SK 3 Turn on the mains to the Art380 4 Remove the short...

Page 14: ...hile talking to the door 7 Note To go back to the door call simply hang up and then pick up again To open the door without first being called 0 To open the door during a call 0 To put the system in di...

Page 15: ...he relay has been programmed to be either normally closed when it should be normally open or normally open when it should be normally closed Reprogram the Art380 relay reverse correctly The Art380 doe...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Reviews: