12.1 Maintaining
Maintenance must be carried out by
personnel trained to operate on electrical
circuits.
12.1.1 Fuses replacement
Maintenance must be performed with the
power supply disconnected and the circuit-
breaker open.
F1
F2
Fig.
83
FUSES REPLACEMENT
Voltage
Fuse F1
Fuse F2
24Vac, 50/60Hz
F 6.3A L 250V 5x20
T 8A H 250V 5x20
120Vac, 50/60Hz
F 6.3A L 250V 5x20
T 4A H 250V 5x20
230Vac, 50/60Hz
F 6.3A L 250V 5x20
T 2A H 250V 5x20
Tab.