background image

8

ENGLISH

Vandal resistant camera housing and accessories

TECHNICAL SPECIFICATIONS

Housing

-External dimensions:

355x155x178 mm (14x6.1x7 in)

-Weight:

3,5 kg (7.7 lb)

-Material:

Varnished steel plate, RAL 9002 colour

-

Operating temperature

:From -20°C to +50°C (from -4°F to +122°F)

Heater

-Size:

93x45x10,4 mm (3.7x1.8x0.4 in)

-Power supply:

12V DC/24V AC, 20W or 115/230V AC, 40W

-Temperature ON:

< 15°C +/- 3°C (< 59°F +/- 5°F)

-Temperature OFF:

> 22°C +/- 3°C (> 72°F +/- 5°F)

Cable glands

-M20 cable gland:

Ø cable 7÷13 mm (0.3÷0.5 in)

-Fixing tork:

7 Nm

Camera power supply

1) (Fig. 6)

-Size:

75,5x50x32,3 mm (3x2x1.3 in)

-Input voltage:

100-240V AC

-Output voltage:

12V DC

-Output current:

1A

-

Weight

:

0,123 kg (0.27 lb)

2) (Fig. 7)

-Size:

67,2x52,2x40 mm (2.6x2x1.6 in)

-Input voltage:

230V AC

-Output voltage:

24V AC

-Output current:

400 mA

-

Weight

:

0,380 kg (0.83 lb)

Wall or ceiling fixing

-Fixing dist. between centers:

155x105/65 mm (6.1x4.1/2.6 in) (Fig. 10)

MNVCAVTPSC_0604  2-03-2006  17:13  Pagina 8

Summary of Contents for MNVCAVTPSC 0604

Page 1: ...ons Manuale istruzioni Custodia antivandalismo per telecamera ed accessori Vandal resistant camera housing and accessories Caisson antivandalisme pour camera video et accessoires Antivandalismus Kamer...

Page 2: ...I N D E X ENGLISH Camera housing and accessories NORMES DE SECURIT 9 DESCRIPTION 9 Accessoires disponibles 9 Entretiens de la vitre et des parties en plastique PC 9 INSTALLATION 9 Ouverture du caisson...

Page 3: ...lit alla telecamera alle ottiche e a tutte le sue connessioni Questa custodia compatibile con telecamere da 1 2 1 3 e 1 4 con obbiettivi a focale fissa o piccoli zoom in commercio La serratura d apert...

Page 4: ...ne della resistenza precablata utilizzando il morsetto predisposto sul circuito d appoggio Fig 4 5 Chiudere la custodia Nel circuito c anche la possibilit di prelevare l alimentazione per una telecame...

Page 5: ...AC 40W Temperatura ON 15 C 3 C Temperatura OFF 22 C 3 C Pressacavi Pressacavo M20 cavo 7 13 mm Coppia di serraggio 7 Nm Alimentatore per telecamera 1 Fig 6 Ingombro 75 5x50x32 3 mm Tensione di ingress...

Page 6: ...lable on the market with either fixed focus or small zoom lenses The lock for opening and closing the housing is located on the front and can be supplied with either a universal or a uniquely coded ke...

Page 7: ...om an external source pay attention to the type of working voltage and use the correct power supply kit according to requirements Camera power supply installation This chapter describes how to install...

Page 8: ...40W Temperature ON 15 C 3 C 59 F 5 F Temperature OFF 22 C 3 C 72 F 5 F Cable glands M20 cable gland cable 7 13 mm 0 3 0 5 in Fixing tork 7 Nm Camera power supply 1 Fig 6 Size 75 5x50x32 3 mm 3x2x1 3 i...

Page 9: ...les cam ras de 1 2 1 3 et 1 4 avec objectifs focale fixe ou petits zooms disponibles dans le commerce La serrure d ouverture est install e sur la partie frontale et peut tre fournie avec une cl univer...

Page 10: ...support Fig 4 5 Fermer le caisson Dans le circuit il est aussi possible de pr lever l alimentation pour une cam ra En alimentant le circuit partir d une source externe il faut faire attention au type...

Page 11: ...230V AC 40W Temp rature ON 15 C 3 C Temp rature OFF 22 C 3 C Presse toupes Presse c ble M20 c ble 7 13 mm Couple de serrage 7 Nm Alimentation pour camera 1 Fig 6 Encombrement 75 5x50x32 3 mm Tension...

Page 12: ...enk ffnung macht es installations und wartungsfreundlich die Videokamera die Optiken und Anschl sse sind bequem erreichbar Dieses Geh use ist kompatibel mit handels blichen Kameras 1 2 1 3 und 1 4 mit...

Page 13: ...ich bereits auf der Tr gerschaltung befindet Fig 4 5 Das Geh use schlie en Die Schaltung bietet daneben die M glichkeit die Strom versorgung f r eine Kamera abzugreifen Speist man den Schaltkreis aus...

Page 14: ...mperatur ON 15 C 3 C Temperatur OFF 22 C 3 C Kabelschellen Kabelschelle M20 Kabel 7 13 mm Anzugsdrehmomente 7 Nm Netzteil f r Kamera 1 Fig 6 Ausma e 75 5x50x32 3 mm Eingangsspannung 100 240V AC Ausgan...

Page 15: ...15 2 1 2 2 Fig 2 Fig 1 H MNVCAVTPSC_0604 2 03 2006 17 13 Pagina 15...

Page 16: ...15 230V AC HEATER OUT 115 230V AC CAMERA OUT 115 230V AC Fig 4 IN 100 240V AC HEATER OUT 100 240V AC CAMERA OUT 12V DC 24V AC Fig 5 Fig 6 Fig 7 3 1 3 2 3 3 3 4 Fig 3 MNVCAVTPSC_0604 2 03 2006 17 13 Pa...

Page 17: ...17 8 1 8 2 8 5 8 6 8 4 8 3 Fig 8 APRIRE CON UTENSILE OPEN WITH A TOOL OUVRIR AVEC UN OUTIL DURCH DAS WERKZEUG FFNEN Fig 9 MNVCAVTPSC_0604 2 03 2006 17 13 Pagina 17...

Page 18: ...18 164 5 46 145 155 55 25 25 105 9 65 Fig 10 MNVCAVTPSC_0604 2 03 2006 17 13 Pagina 18...

Page 19: ...e Haftung f r eventuelle Sch den ab die aufgrund unsachgem er Anwendung der in diesem Handbuch erw hnten Ger te entstanden ist Ferner beh lt er sich das Recht vor den Inhalt ohne Vork ndigung abzu nde...

Page 20: ...MNVCAVTPSC_0604 MNVCAVTPSC_0604 2 03 2006 17 13 Pagina 20...

Reviews: