Page 3 DTRX1 9941
Operating data on the rating plate
The DTRX1 receiver is supplied with two rating plates in conformity with the EC standards.
The first plate contains:
•
Modell identification code (Extended 3/9 bar code)
•
Power supply (Volt)
•
Frequency (Hertz)
•
Consumption (Watt)
The second plate indicates the serial number of the model (Extended 3/9 bar code).
During the installation phase, make sure that the power supply features of the receiver correspond to the
characteristics required. The use of unsuitable devices can lead to serious risks for the safety of the personnel and the
security of the plant.
Description of the DTRX1 receiver
The DTRX1 receiver is a microprocessor-based command receiver for the remote control of positioning
devices, motorized lenses, wiper, washer and auxiliary functions.
Features
•
17 Functions: UP, DOWN, LEFT, RIGHT, AUTO, WASHER, WIPER, ZOOM TELE, ZOOM WIDE, FOCUS NEAR,
FOCUS FAR, IRIS OPEN, IRIS CLOSE, AUX1, AUX2, AUX3, AUX4
•
Power supplied to the camera: 12 V
=
(AUX1) and 24 V~ (AUX2)
•
2 dry contacts: range 1A 24VDC (AUX3, AUX4)
•
99 selectable addresses
•
Serial input selectable between RS-232 / Current Loop / RS485
•
Selectable communication speed (9600 / 2400 / 1200 / 300 Baud)
•
Current Loop repeater for in-line configuration
•
Possibility of using both polarity inversion lenses and common wire lenses
•
Digital logic and part of optoisolated power
•
Led indicating power supplied to the unit
•
Service socket
•
Led indicating active function
•
EEPROM for the storage of active options
•
BNC for video connection
•
Trimmer for the adjustment of the lens voltage (from 2.5V
=
to 15V
=
)
•
PRESET / SCAN / PATROL functions, 4 alarm contacts with optional DTRP card
•
Optional TWT card for the transmission of the video signal by means of a twisted pair
•
Power supply:
230 V~ 50 Hz
•
Consumption:
50 W
•
Max switching power:
100W
•
Power supplied to the positioning device: 24/230 V~ 50 Hz
•
Power supplied to the wiper:
24/230 V~ 50 Hz
•
Power supplied to the washer:
230 V~ 50/60 Hz
•
Power supplied to the lens:
from 2.5V
=
to 15 V
=
•
Fuses:
F1-F5: 630 mAF 250V
F2: 1.6 AF 250V
F3-F4: 1AF 250V
F6: 1.6 AF 250V
Compatible devices for the use with the DTRX1 receiver
•
DCS3, DCS2, DCMT8
: control keyboard.
•
communication controller
DCMX
: it allows the operator to control one or more receivers (up to 8 lines) by means of
several keyboards (up to 4).
Summary of Contents for DTRX1
Page 1: ...MANUALE D USO OPERATING INSTRUCTIONS MANUEL D INSTRUCTIONS BEDIENUNGSANWEISUNG 7 7 5 5 4 4...
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ...MANUALE D USO D D D D T T T T R R R R X X X X 1 1 1 1...
Page 8: ......
Page 24: ......
Page 25: ...OPERATING INSTRUCTIONS D D D D T T T T R R R R X X X X 1 1 1 1...
Page 26: ......
Page 42: ......
Page 43: ...MANUEL D INSTRUCTIONS D D D D T T T T R R R R X X X X 1 1 1 1...
Page 44: ......
Page 60: ......
Page 61: ...BEDIENUNGSANWEISUNG D D D D T T T T R R R R X X X X 1 1 1 1...
Page 62: ......
Page 78: ......
Page 79: ......
Page 80: ......