background image

Dry contact

Existing control 

panel

1.4 XTENDER mode

The  Videofied

® 

W panel can be used as a standalone alarm system.

When fitted with the WIO100 input/outputs module, it can also be wired to an 

existing alarm system

 with a 

programmable dry contact.

When used in XTENDER mode, the W panel can only be armed when the programmed condition for arming is met.

For example, if the XTENDER input type parameter is set as 

normally open

, the system 

will arm

 when 

the circuit 

is closed

.

Opening the circuit will disarm the panel.

4

W Panel 

www.videofied.com

WIO 100 Input/Outputs module

When used in XTENDER mode, 

arming devices

 (keypads, keyfobs, badge readers) 

cannot arm or disarm the system

To switch between standalone mode and XTENDER mode, go to the menu :

CONFIGURATION

 (Lvl 4) > 

GENERAL PARAMETERS 

XTENDER

Note : 

Enabling the programmable input will automatically disable the XTENDER mode and switch the W panel in standalone 
mode. In the same manner, enabling the XTENDER mode will automatically disable the programmable input.

Like when it is used as a 

programmable input, the 

WIO100 input used as an 

XTENDER arming input can 

be supervised thanks to the 

two 4.7k

Ω

 resistors provided 

with the module.

A P P L I C A T I O N   N O T E

Summary of Contents for WIO100

Page 1: ...g the programmable input can be set up to take a 10 second video from any Videofied Motion Viewer when the detector linked to the programmable input is triggered The programmable input can also be wired to an existing alarm system in order to add video vérification That mode is called XTENDER mode Programmable outputs are normally open drys contacts that close when the output is activated Index 1 ...

Page 2: ...tc You can find the event list on the next page Entry delay in seconds between the input triggering and the alarm triggering event transmission 0 3600 seconds Input Name This name can be seen by the monitoring center when the input triggers Choose a detailed name Siren type for the programmable input Siren the siren will be enabled and the keypad will beep Silent no siren no beeps Without siren on...

Page 3: ...nked device triggering The security server will receive this event when the programmable input triggers Important These events are different from the events transmitted list in the FRONTEL SECURITY PARAMETERS menu They will be sent no matter how the events listed in the EVENT TRANS MODIFICATION are set 1 3 Programmable input wiring and supervision Programmable input wiring IN IN OUT1 OUTN OUT2 Pro...

Page 4: ...the panel 4 W Panel www videofied com WIO 100 Input Outputs module When used in XTENDER mode arming devices keypads keyfobs badge readers cannot arm or disarm the system To switch between standalone mode and XTENDER mode go to the menu CONFIGURATION Lvl 4 GENERAL PARAMETERS XTENDER Note Enabling the programmable input will automatically disable the XTENDER mode and switch the W panel in standalone...

Page 5: ... YES to select the parameter Enter the value for your Entry Delay up to 255 seconds and press OK or YES Note In From the Host mode the entry exit delay are managed by the master system Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input This feature can be used as an exit delay we suggest you to enter the same value as your master s...

Page 6: ...UT 1 programmable output connection 2 Programmable outputs 2 1 Programmable outputs triggering INTRUSION TAMPER PANICBUTTON INCORRECTCODE DURESSCODE1 DURESSCODE2 SUPERVISION RADIOJAMMING LOWPANELBATT LOWDEVICEBATT ACPOWERMISS PANELRESET SYSTEMARMED SYSTEMDISARMED PERIODICTEST ALARMCANCEL SMOKEDETECTION PHONELINE MISS TMT REQUEST MEDICAL ASSIST ETHERNET CABLE DETECTION PROG INPUT1 You can find belo...

Page 7: ...ammable output in cas of alarm EVENT TYPE INTRUSION Type of event assigned to the input intrusion smoke detection tamper assistance detection etc When the event occurs the output will activate OUTPUT NAME OUTPUT 1 Output name In order to recognize which system is connected to the output choose a detailed name 7 North American Headquarters 1375 Willow Lake Blvd Suite 103 Vadnais Heights MN 55110 US...