1.2 Types d’évenements
INTRUSION
TAMPER
PANIC BUTTON
INCORRECT CODE
DURESS CODE 1
DURESS CODE 2
SUPERVISION
RADIO JAMMING
LOW PANEL BATT.
LOW DEVICE BATT.
AC POWER MISS
PANEL RESET
SYSTEM ARMED
SYSTEM DISARMED
PERIODIC TEST
ALARM CANCEL
SMOKE DETECTION
PHONLINE MISS.
TMT REQUEST
MEDICAL ASSIST.
ETHERNET CABLE
DETECTION
The programmable input can be assigned to different event types according to the source
of the linked device triggering.
The security server will receive this event when the programmable input triggers.
Important :
These events are different from the events transmitted list in the FRONTEL SECURITY
PARAMETERS menu. They will be sent no matter how the events listed in the EVENT
TRANS. MODIFICATION are set.
1.3 Programmable input wiring and supervision
Programmable input wiring
IN +
IN -
OUT 1
OUT N
OUT 2
Programmable input supervision
4.7k
Ω
4.7k
Ω
Wired detection device
Connect two 4,7k
Ω
resistors (provided) as shown in the above scheme.