background image

1.  Programmable input

The programmable input is triggered by a 

dry contact

 connected to its terminals switches. 

1.1 Programmable input menu

PROGRAMMABLE 

INPUT

GENERAL 

PARAMETERS

Niv. 4

CONFIGURATION

OK 

or 

YES

OK 

or 

YES

TRANSMISSION

DISABLED

PROGRAMMABLE 

INPUT

SUPERVISION

MAPPING

DISABLED

SEND EVENT

ALARM

EVENT TYPE

INTRUSION

ENTRY DELAY

20

SIREN MODE

SIREN

INPUT NAME

INPUT 1

DETECTION NB

0

INPUT TYPE

NORMALLY OPEN

Sets if and how the input is armed

Enabled 

: 24h active input (example : panic button).

Disabled

 : Disabled input.

Only if armed

 : Input disabled when the panel is disarmed.

Alarm : the event is transmitted upon input triggering
Alarm / End : the event is transmitted upon imput triggering and on event restoral.

Normally Open : Short circuit will trigger the input.
Normally closed : Open circuit will trigger the input.

Type of event assigned to the input

 (intrusion, smoke detection, tamper, assistance 

detection, etc...).
You can find the event list on the next page.

Entry delay in seconds between the input triggering and the alarm triggering/event 
transmission.
0-3600 seconds.

Input Name. This name can be seen by the monitoring center when the input triggers. 
Choose a detailed name.

Siren type for the programmable input

Siren : the siren will be enabled and the keypad will beep.
Silent : no siren, no beeps.
Without siren : only the keypad beeps.

Links a Videofied® MotionViewer to the input. 

When the input triggers, the linked camera will record a video and transmit it to the 
security server.

Generates a welcome ring

 on the keypad and indoor siren when the input is 

triggered. For more information, please refer to the Chime Application Note.

Only displayed if the event type is Detection.

 The monitoring center assign this number to the detection type.

CHIME

PARAMETERS

SC & OC Superv. : 

Enables the programmable input supervision (open and short 

circuit).

Transmission : 

Type of transmission sent to the security server (Alarm, Alarm/End 

and Not transmitted).

2

W Panel 

www.videofied.com

WIO 100 Input/Outputs module

A P P L I C A T I O N   N O T E

Summary of Contents for WIO100

Page 1: ...g the programmable input can be set up to take a 10 second video from any Videofied Motion Viewer when the detector linked to the programmable input is triggered The programmable input can also be wired to an existing alarm system in order to add video vérification That mode is called XTENDER mode Programmable outputs are normally open drys contacts that close when the output is activated Index 1 ...

Page 2: ...tc You can find the event list on the next page Entry delay in seconds between the input triggering and the alarm triggering event transmission 0 3600 seconds Input Name This name can be seen by the monitoring center when the input triggers Choose a detailed name Siren type for the programmable input Siren the siren will be enabled and the keypad will beep Silent no siren no beeps Without siren on...

Page 3: ...nked device triggering The security server will receive this event when the programmable input triggers Important These events are different from the events transmitted list in the FRONTEL SECURITY PARAMETERS menu They will be sent no matter how the events listed in the EVENT TRANS MODIFICATION are set 1 3 Programmable input wiring and supervision Programmable input wiring IN IN OUT1 OUTN OUT2 Pro...

Page 4: ...the panel 4 W Panel www videofied com WIO 100 Input Outputs module When used in XTENDER mode arming devices keypads keyfobs badge readers cannot arm or disarm the system To switch between standalone mode and XTENDER mode go to the menu CONFIGURATION Lvl 4 GENERAL PARAMETERS XTENDER Note Enabling the programmable input will automatically disable the XTENDER mode and switch the W panel in standalone...

Page 5: ... YES to select the parameter Enter the value for your Entry Delay up to 255 seconds and press OK or YES Note In From the Host mode the entry exit delay are managed by the master system Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input This feature can be used as an exit delay we suggest you to enter the same value as your master s...

Page 6: ...UT 1 programmable output connection 2 Programmable outputs 2 1 Programmable outputs triggering INTRUSION TAMPER PANICBUTTON INCORRECTCODE DURESSCODE1 DURESSCODE2 SUPERVISION RADIOJAMMING LOWPANELBATT LOWDEVICEBATT ACPOWERMISS PANELRESET SYSTEMARMED SYSTEMDISARMED PERIODICTEST ALARMCANCEL SMOKEDETECTION PHONELINE MISS TMT REQUEST MEDICAL ASSIST ETHERNET CABLE DETECTION PROG INPUT1 You can find belo...

Page 7: ...ammable output in cas of alarm EVENT TYPE INTRUSION Type of event assigned to the input intrusion smoke detection tamper assistance detection etc When the event occurs the output will activate OUTPUT NAME OUTPUT 1 Output name In order to recognize which system is connected to the output choose a detailed name 7 North American Headquarters 1375 Willow Lake Blvd Suite 103 Vadnais Heights MN 55110 US...

Reviews: