2. Description 
 

VE.Direct communication port 

The VE.Direct port can be connected to: 

  A computer (VE.Direct to USB interface cable needed) 

  Apple and Android smartphones, tablets and other devices (VE.Direct to Buetooth 

Low Energy (BLE) dongle needed) 

 

Fully configurable 

  Low and high battery voltage alarm trip and reset levels 

  Low and high battery voltage cut-off and restart levels 

  Output voltage 220/230/240V 

  Frequency 50 Hz or 60 Hz 

  ECO mode on/off and ECO mode sense level 

 

Monitoring 

Battery voltage and current, AC Output voltage and current, alarms 
 

Proven reliability 

The full bridge with toroidal transformer topology has proven its reliability over many 
years. 
The inverters are short circuit proof and protected against overheating, whether due 
to overload or high ambient temperature. 
 

High start-up power 

Needed to start loads such as power converters for LED lamps, filament lamps or 
electric tools. 
 

ECO mode 

When in ECO mode, the inverter will switch to standby when the load decreases 
below a preset value. It will switch on and check every few seconds, adjustable, if the 
load has increased again.. 
 

Remote on/off connector 

A remote on/off switch can be connected to a two pole connecter or between battery 
plus and the left hand contact of the two pole connector. 
 

LED diagnosis 

A red and a green LED indicate inverter operation and status of the different 
protections. 
 

Available with different output sockets 

Schuko, UK (BS-1363), AU/NZ (3112) or IEC-320 (male plug included) 

Summary of Contents for Phoenix 12/250

Page 1: ...Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 24 250 24 375 48 250 48 375...

Page 2: ......

Page 3: ...assis must be grounded A grounding point is located on the outside of the product Whenever it is likely that the grounding protection has been damaged the product must be turned off and secured agains...

Page 4: ...reliability over many years The inverters are short circuit proof and protected against overheating whether due to overload or high ambient temperature High start up power Needed to start loads such a...

Page 5: ...C circuit breaker must be inserted close to the battery Reverse polarity connection of the battery wires will blow the internal fuse and can damage the inverter The internal fuse it not replacable 3 2...

Page 6: ...LED indicates the reason for shutdown Remove the cause and then restart the inverter by switching it Off and then back On Red LED Definition Trouble shooting Solid on Overload Reduce load Slow blink L...

Page 7: ...it Off and then On or recharge the battery as soon as the battery has risen and then stayed above the Charge detect level for 30 seconds it will switch on See the Technical Data table for default low...

Page 8: ...2 a f Operating temperature range 40 to 60 C fan assisted cooling derate 3 per C above 40 C Humidity non condensing max 95 ENCLOSURE Material Colour Steel chassis and plastic cover blue Ral 5012 Batt...

Page 9: ...EN NL FR DE ES Appendix the Digital Multi Control Fig 1 Front and rear view FigFi...

Page 10: ...00 Date 20 January 2016 Victron Energy B V De Paal 35 1351 JG Almere PO Box 50016 1305 AA Almere The Netherlands General phone 31 0 36 535 97 00 Customer support desk 31 0 36 535 97 03 Fax 31 0 36 535...