1. Safety instructions 

 
WARNING: ELECTRIC SHOCK HAZARD 

The product is used in conjunction with a permanent energy source (battery). Input 
and/or output terminals may still be dangerously energized, even when the equipment 
is switched off. Always disconnect the battery before carrying out maintenance or 
servicing the product. 
 
The product has no internal user-serviceable components. Do not remove the front 
plate or operate the product if any panels have been removed. All servicing must be 
undertaken by qualified personnel. 
 
Please read the installation instructions in the installation manual before installing the 
equipment. 
 
This is a Safety Class I product (supplied with a protective grounding terminal). The 
chassis must be grounded. A grounding point is located on the outside of the product. 
Whenever it is likely that the grounding protection has been damaged, the product 
must be turned off and secured against unintended operation; please contact qualified 
service staff. 
 
The AC output is isolated from the DC input and the chassis. Local regulations may 
require a true neutral. In this case one of the AC output wires must be connected to 
the chassis, 

and the chassis must be connected to a reliable ground

. Please note 

that a true neutral is needed to ensure correct operation of an earth leakage circuit 
breaker. 
 
Ensure that the equipment is used under the correct ambient conditions. 

Never operate the product in a wet or dusty environment.

 

Never use the product where there is a risk of gas or dust explosions. 
 

Ensure there is adequate free space (10 cm) for ventilation around the product and 
check that the ventilation vents are not blocked. 

Summary of Contents for Phoenix 12/250

Page 1: ...Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 24 250 24 375 48 250 48 375...

Page 2: ......

Page 3: ...assis must be grounded A grounding point is located on the outside of the product Whenever it is likely that the grounding protection has been damaged the product must be turned off and secured agains...

Page 4: ...reliability over many years The inverters are short circuit proof and protected against overheating whether due to overload or high ambient temperature High start up power Needed to start loads such a...

Page 5: ...C circuit breaker must be inserted close to the battery Reverse polarity connection of the battery wires will blow the internal fuse and can damage the inverter The internal fuse it not replacable 3 2...

Page 6: ...LED indicates the reason for shutdown Remove the cause and then restart the inverter by switching it Off and then back On Red LED Definition Trouble shooting Solid on Overload Reduce load Slow blink L...

Page 7: ...it Off and then On or recharge the battery as soon as the battery has risen and then stayed above the Charge detect level for 30 seconds it will switch on See the Technical Data table for default low...

Page 8: ...2 a f Operating temperature range 40 to 60 C fan assisted cooling derate 3 per C above 40 C Humidity non condensing max 95 ENCLOSURE Material Colour Steel chassis and plastic cover blue Ral 5012 Batt...

Page 9: ...EN NL FR DE ES Appendix the Digital Multi Control Fig 1 Front and rear view FigFi...

Page 10: ...00 Date 20 January 2016 Victron Energy B V De Paal 35 1351 JG Almere PO Box 50016 1305 AA Almere The Netherlands General phone 31 0 36 535 97 00 Customer support desk 31 0 36 535 97 03 Fax 31 0 36 535...

Reviews: