VictronCo
nnect
warning
code
GX device
warning
code
Message
Instructions / remarks
W-D04
#224
Communication with distributor D
lost
Check the cable between BMS and Distributor.
VictronCo
nnect
alarm code
GX device
alarm code
Message
Instructions / remarks
A-B01
#103
Low cell voltage
Charge battery. The system will turn the loads back
on when the battery is sufficiently charged.
A-B02
#105 or
#106
High current
Reduce charging current or turn off some loads. The
system will try to re-enable chargers or loads in 5
minutes.
A-B06
-
Load disconnected
The loads have been turned off via the ATD contact
and/or via the GX device. Resolve this alarm by
charging the battery. If not resolved, eventually the
contactor will open and the DC system will be
disconnected.
VictronCo
nnect error
code
GX device
error code
Message
Instructions / remarks
E-B09
#09
Battery voltage not allowed
The battery voltage is too high or too low. Check the
battery voltage and check the battery settings in the
VictronConnect app.
This error occurs when the battery voltage is
outside all system voltage ranges (9V > Vbat > 60V)
E-B11
#11
Hardware error
Contact your Victron dealer.
E-B25
#25
Pre-charge error
The load resistance is too low to pre-charge the
loads. Disconnect or reduce some DC loads.
E-B26
#26
Contactor error
Contact your Victron dealer.
E-B34
#34
Wrong system voltage
Check battery voltage settings in the
VictronConnect app.
E-B35
#35
Pre-charge timeout
The load capacity is too high to pre-charge.
Disconnect some DC loads.
E-B36
#36
ATC/ATD failure
Check ATC/ATD wiring and make sure that all loads
and chargers are controlled by ATC or ATD.
E-B119
#119
Settings data lost
Settings data is corrupt. Go to the settings page and
reset to defaults.
GX device code
VictronConnect code
Message
#201
A-F01
Fuse "Fuse_1" is blown
#202
A-F02
Fuse "Fuse_2" is blown
#203
A-F03
Fuse "Fuse_3" is blown
#204
A-F04
Fuse "Fuse_4" is blown
#205
A-F05
Fuse "Fuse_5" is blown
#206
A-F06
Fuse "Fuse_6" is blown
#207
A-F07
Fuse "Fuse_7" is blown
#208
A-F08
Fuse "Fuse_8" is blown
#209
A-F09
Fuse "Fuse_9" is blown
#210
A-F10
Fuse "Fuse_10" is blown
Lynx Smart BMS
Page 33
Appendix