IMPORTANT: Observe all governing codes and ordinances. 

It is the customer’s responsibility:

• 

To contact a qualified electrician

• 

To assure that the electrical installation is adequate and in conformance with National Electrical 

Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, 

Part 1 and C22. 2 No. 0-M91 - latest edition** and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician de-

termine that the ground path is adequate.

A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit.

DO NOT ground to a gas pipe.

Check with a qualified electrician if you are not sure that the range hood is properly grounded.

DO NOT have a fuse in the neutral or ground circuit.

IMPORTANT: Save this Installation Guide for electrical inspector’s use.

The range hood must be connected with copper wire/plug only.

The range hood should be connected directly to the fused disconnect (or circuit breaker) box through 

flexible armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be 

provided at each end of the power supply cable.

Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specified on 

the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code 

ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22. 

2 No.  0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit con-

nector must be provided at each end of the power supply cable (at the range hood and at the junction box).

 

Copies of the standards listed may be obtained from:

*   National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

**

 

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

ELECTRICAL REQUIREMENTS

Summary of Contents for SUNSET

Page 1: ...2u 3a Model Name SUNSET Ceiling Mount Range Hood NOTICE For residential use only Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference INSTALLATION GUIDE AND USERS MANUAL ...

Page 2: ...anel to prevent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics and or garages Ducted fans MUST always be vented to the outdoors Use only metal ductwork and this unit MUST be grounded Sufficient air is neede...

Page 3: ...all doors and windows to disperse the gas If you still smell gas call the gas company and fire department or dial your local emergency service immediately Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages All safety messages will tell you what the potential hazard is t...

Page 4: ... SUNSET 4 REQUIRED TOOLS ...

Page 5: ...rmance Use aluminum foil tape to seal all joints in the vent system Use caulking to seal exterior wall or roof opening around the cap Use 45 degree elbows instead of 90 degree elbows when possible IMPORTANT A minimum of a 6 round duct standard for this range hood must be used to maintain maximum airflow efficiency Always use rigid type metal aluminum ducts if available to maximize airflow when con...

Page 6: ...uct run Subtract 30ft from the allowable 50ft The remaining distance of 20ft is the longest that the straight ducting in ad dition to the vent pieces can be To calculate the length of the duct system you require subtract the equivalent feet for each Vent piece Table Below used in the system from the Recommended maximum run Table Below The longest duct run that is acceptable if completely straight ...

Page 7: ...trical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wiresizes copperwireonly andconnectionsmustconformwiththeratingoftheappl...

Page 8: ...the existence of all supplied parts Carefully remove the white or blue plastic protective coat from the range hood Preparations NOTE To avoid damage to your hood prevent debris from entering the vent opening Decide the location of the venting pipe from the hood to the outside Refer to Venting Methods A straight short vent run will allow the hood to perform more efficiently Try to avoid as many tra...

Page 9: ...SUNSET The range hood should be placed at a maximum distance of about 8 from the floor for best performance The ceiling should be able to bear 27 Kg in weight Installation 9 INSTALLATION DIAGRAMS ...

Page 10: ...l spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal aluminum duct work only Fasten all connections with sheet metal screws and tape all joints with certified Aluminum Tape Use caulking to seal exterior wall or roof opening around the cap If the duct is running though a cold section of the house attic space insultion of the duct will be required to prevent condens...

Page 11: ...SUNSET DIMENSIONS CUT OUT 11 ...

Page 12: ...on between the joists Please NOTE The orientation of the joists and the orientation of the stove must match If the orientation does not match the range hood may need to be dropped down into a box in order to rotate it INSTALLATIONS DIAGRAMS 12 ...

Page 13: ...SUNSET WIRING DIAGRAM 13 ...

Page 14: ...ITCH This hood will come with a Wall Switch to operate the lights and motor The lights have an On Off switch and are dimmable The motor has a 4 speed switch FRONT BACK ROTARY FAN SWITCH 4 SPEEDS LIGHT DIMMER SWTICH RANGE HOOD OPERATIONS HOOD WALL SWITCH ...

Page 15: ...tion efficiently with insufficient duct size For example Connecting this hood to 4 or 5 duct will reduce the suction and create extra noise and vibrations Check if duct is clogged or if damper unit is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow 4 The lights work but the blower is not spinning at all is stuck or is ra...

Page 16: ...and worn filters must be replaced immediately DO NOT operate blowers when filters are removed Never disassemble parts to clean without prop er instructions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding Body Design Seamless Stainless Steel Brushed Finish or White Power Rating 120V 60Hz USA Ca...

Page 17: ...rub lightly a with clean cotton cloth and with the grain DO NOT allow deposits to accumulate or remain on the hood DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stain less steel for extended periods Many of these compounds contain chem...

Page 18: ...removed has not been handled or packaged correctly or has been sold as second hand What is Not Covered Consumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage o...

Page 19: ...st be returned in good working condition with ALL original parts and documentation packed in all original cartons fillers and shipping cartons A restocking fee of 10 will be charged for all approved return s Exchanges or returns will not be accepted if the unit has been installed and may be rejected if parts are missing Make sure to inspect the hood for damages and defects before installation Appe...

Page 20: ...583 Nicola Avenue Port Coquitlam BC Canada V3B 0M3 www kitchenhoods ca ...

Reviews: