Victoria-05 Ltd.
6
4.
Safety devices.
Fume thermocouple:
It is placed on the top part of the integral boiler to measure the temperature of the flue gases. It
controls ignition. At a very high temperature (500°C) an alarm
„High Temp”
appears on the display.
Pressostat
: two outlets placed at the air outlet and connected to the control unit. In case of disruption of the rarefaction
in the combustion chamber, a
„Pressostat”
alarm appears on the display.
Thermostat:
To prevent overheating of the system, with manual reset. Measure the temperature of the water into the
integral boiler. When it reaches a value of 90°C, it interrupts power to the gear motor of the auger. If the thermostat has
been activated, it must be reset manually by pressing the switch on the back of the pellet stove (see Fig.1, position H).
Thermostat of the pellet fuel hopper:
Placed on the auger housing near the pellet fuel hopper. It interrupts feeding of
the pellets, if its temperature reaches 75°C.
Temperature sensor:
Measure the temperature of the water into the integral boiler and sends information to the
control system.
Hydraulic safety valve:
Upon reaching a pressure of 3.0 bar, the system is activated to emit liquid. After discontinuation
of the emergency, the system must be added to the required pressure (1.5 bar).
Fuse:
At the main switch of the pellet stove has built two fuses, one of whom is working and the other is a spare.
5.
Control system.
The control system is capable to monitor and control the combustion process. The system provides higher heat efficiency,
optimizes the pellet consumption and minimizes the emissions level into the atmosphere. By sensors for room temperature,
back burn, temperature of exhaust gasses and temperature into integral boiler, the control system reads and analyzes data from
the combustion process and automatically controls it.
OUT1-
Pump
OUT2-
Ignition
OUT3-
Smoke Fan
OUT4-
Screw Conveyor
OUT5- Not applicable
OUT6- Not applicable
OUT7- Not applicable
OUT8- Not applicable
АIN1-
Indoor Temperature
Sensor
АIN2- Not applicable
АIN3-
Reverse Combustion
АIN4-
Water Heater
Sensor
АIN5- Not applicable
POWER-
Input Socket 230V
HALL-
Smoke Fan Turns
Input
Т2-
0°С - 1024°С
-
Thermocouple Input
LED- Not applicable
PHT- Not applicable