11.Instruction manual.
11.1. Wood pellets loading.
The capacity of the pellet fuel hopper is 26 kg. The opening for charging the hopper is with dimensions 150 х 320 mm.
If the hopper is left without pellets, the pellet stove will stop working and
„Fire extinct“
alarm will be shown on the display.
11.2. Wood pellet refueling.
When the pellet fuel hopper is completely empty, it means that the screw auger is also empty. Before re-ignite the pellet stove,
it is necessary to load it with wood pellets.
During initial igniting of the pellet stove or during igniting of the stove after the pellet hopper was empty, it is possible the
startup procedure to be repeated.
It is possible that sometimes few pellets to be left in the hopper. Once a month the user has to clean the pellet hopper with
vacuum cleaner in order to avoid clogging with dust and particles.
11.3.Starting up the system.
To start the Control Unit, one needs to hold the icon, showing the processes, for at least 3 seconds, which will produce a sound
signal to announce the system’s being started.
To stop the Control Unit, one needs to hold the icon, showing the processes, again for 3 seconds, which will transfer the device
into Clean Mode
and Ready Mode .
On starting the Control Unit, its first task will be to check what stage has been the fireplace on at the time of the previous
stopping. If it has been in any other mode, different from Ready Mode, the Control Unit would either perform Clean and
Transition to Ready Mode, or transit to Stop Mode and Green Eco Mode
. The first mode after Ready Mode is Start Mode
In this mode, what happens is the so called initial clean, which lasts 60 seconds by default. The smoke fan is set on maximum
speed to clean the ashtray. If we would like, we can change the time for initial clean in the Clean Menu.
When the time is over, the device transfers to Fuel Mode
. In this mode there is a countdown as well. The screw conveyor
gets active and starts fueling on impulses within the following period – 2 seconds fuels/ 3 seconds rests .
The ignition (switch) is also active now.
In this mode one can regulate the operation time. Regulating it defines what quantity of
pellets is released. Changing it is possible in the Ignition/ Initial Fuel Menu.
When the time is over, the device transfers to Ignition Mode
. In this mode the ignition
switch is still active, the screw conveyor can be set in time for fuel and rest, and will keep on
operating.
Setting these parameters can be done in Ignition/ Fuel Screw Conveyor/ Screw Conveyor
Menu.
This mode is a transitory one, to transfer to the next mode the exahust gas sensor needs to detect an increase in the
temperature above the one, which has been preset, in the Ignition/ Temperature On Menu!
The increase must last at least 10 seconds and be with at least 6 degg more than the temperature at which the Control Unit has
entered the Ignition Mode!
If this requirement has not been met and the preset time is over, the device would make a second attempt to fuel; its time has
been preset in the Ignition/ Second Fuel Menu.
If the requirement is met, the device will transfer to Set Fire Mode
.
In this mode, the idea is to set the pellets on fire and get stable flame.
The settings of this mode can be found in the Set Fire Menu. When the time of the Set Fire Mode is
over, the device will transfer to the Modulation Mode.
The first one to start is P5, followed by P4 and in the end P1.