background image

02.2020

 

 

 

INSTRUCTION MANUAL 

for installation and operation of pellet stove

VITTORIA В*

 

 

 

17

 

 

11.Instruction manual. 

11.1. Wood pellets loading. 

The capacity of the pellet fuel hopper is 26 kg. The opening for charging the hopper is with dimensions 150 х 320 mm. 
If the hopper is left without pellets, the pellet stove will stop working and 

„Fire extinct“

 alarm will be shown on the display.   

11.2. Wood pellet refueling. 

When the pellet fuel hopper is completely empty, it means that the screw auger is also empty. Before re-ignite the pellet stove, 
it is necessary to load it with wood pellets.  

During  initial  igniting  of  the  pellet  stove  or  during  igniting  of  the  stove  after  the  pellet  hopper  was  empty,  it  is  possible  the 
startup procedure to be repeated. 

It is possible that sometimes  few pellets to be left  in the  hopper.  Once a  month the user has to clean the pellet  hopper with 
vacuum cleaner in order to avoid clogging with dust and particles. 

11.3.Starting up the system. 

To start the Control Unit, one needs to hold the icon, showing the processes, for at least 3 seconds, which will produce a sound 
signal to announce the system’s being started. 
To stop the Control Unit, one needs to hold the icon, showing the processes, again for 3 seconds, which will transfer the device 

into Clean Mode 

            and Ready Mode           . 

On starting the Control Unit, its first task will be to check what stage has been the fireplace on at the time of the previous 
stopping. If it has been in any other mode, different from Ready Mode, the Control Unit would either perform Clean and 

Transition to Ready Mode, or transit to Stop Mode and Green Eco Mode

 . The first mode after Ready Mode is Start Mode       

In this mode, what happens is the so called initial clean, which lasts 60 seconds by default. The smoke fan is set on maximum 
speed to clean the ashtray. If we would like, we can change the time for initial clean in the Clean Menu. 
                              
                              
 
 
 
 
 
 
 

When the time is over, the device transfers to Fuel Mode 

   . In this mode there is a countdown as well. The screw conveyor 

gets active and starts fueling on impulses within the following period – 2 seconds fuels/ 3 seconds rests . 
 
The ignition (switch) is also active now. 

In this mode one can regulate the operation time. Regulating it defines what quantity of 
pellets is released. Changing it is possible in the Ignition/ Initial Fuel Menu. 

When the time is over, the device transfers to Ignition Mode

 . In this mode the ignition 

switch is still active, the screw conveyor can be set in time for fuel and rest, and will keep on 
operating. 
Setting these parameters can be done in Ignition/ Fuel Screw Conveyor/ Screw Conveyor 

Menu. 
This mode is a transitory one, to transfer to the next mode the exahust gas sensor needs to detect an increase in the 
temperature above the one, which has been preset, in the Ignition/ Temperature On Menu!                             
The increase must last at least 10 seconds and be with at least 6 degg more than the temperature at which the Control Unit has 
entered the Ignition Mode! 
If this requirement has not been met and the preset time is over, the device would make a second attempt to fuel; its time has 
been preset in the Ignition/ Second Fuel Menu. 

If the requirement is met, the device will transfer to Set Fire Mode   

                . 

In this mode, the idea is to set the pellets on fire and get stable flame. 
The settings of this mode can be found in the Set Fire Menu. When the time of the Set Fire Mode is 
over, the device will transfer to the Modulation Mode.                              

 
                                   
    The first one to start is P5, followed by P4 and in the end P1.  
                                     
 

Summary of Contents for Vittoria B

Page 1: ...INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA...

Page 2: ...ONTROL UNIT 12 10 2 3 MAIN MENU 13 10 2 4 INSTALLER SETTINGS 15 10 2 5 SERVICE TECHNICIAN SETTINGS 16 11 INSTRUCTION MANUAL 17 11 1 WOOD PELLETS LOADING 17 11 2 WOOD PELLET REFUELING 17 11 3 STARTING...

Page 3: ...failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the...

Page 4: ...l data and dimensions Fig 1 Air inlet 50 mm Flue socket 80 mm Main switch with integrated socket for power cable D Circulation pump E Cold water inlet G F Hot water outlet G G Outlet pipe G for safety...

Page 5: ...xpansion vessel capacity 8 l Cold and hot water inlets dimensions 3 4 Pellet fuel hopper capacity 26 kg Flue socket diameter 80 mm Heating volume 470 m 3 Net weight 268 kg The dimensions of the heated...

Page 6: ...of the water into the integral boiler and sends information to the control system Hydraulic safety valve Upon reaching a pressure of 3 0 bar the system is activated to emit liquid After discontinuatio...

Page 7: ...onnect the heating system to the sewer 7 Operating mode Pellet stove works with wood pellets These are cylindrical granules made of pressed wood whose combustion is controlled by an electronic control...

Page 8: ...cause blockage of the auger and to stop the operation of the pellet stove IF PELLET STOVE BLOCKED THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED Using low quality wood pellets or non manu...

Page 9: ...lue gases to safe for human health altitude over the area of habitation It is recommended that the pellet stove can be installed as close as possible to the chimney in order to reduce the number of co...

Page 10: ...eat consumers 10 Three way mixing valve thermostatic 11 Stopcock 12 Filter 13 Manometer 6 bar 14 Built in circulation pump The installation hydraulic diagram is indicative and does not replace the doc...

Page 11: ...ig 3 This operation must be repeated in the first days of use and when the system is recharged even partially The presence of air in the heating system can aggravate proper operation of the pellet sto...

Page 12: ...and then it would disappear in this case one can sure that the value has been saved correctly Just in case during the time of saving access to the Back Icon is denied to prevent involuntary interrupt...

Page 13: ...Fan Should one chose Turns then the fan would transfer to Set the Power Mode Should one chose Flow then the Fan would transfer to Flow Supervise Mode Mode of operation Here Heating Mode is firmly fix...

Page 14: ...imer ON shall not be active The delayed start is an autonomous one time timer which one can set a particular date and hour on to start the fireplace Its effect is a one time individual one The third o...

Page 15: ...can be locked in two ways The first one is to hold for more than 3 seconds the Title Page Settings Icon The second one is automatically while transitioning to Standby Mode of the Display in 10 minute...

Page 16: ...an to operate at 100 in Clean Mode This mode gets active if the contol unit transfers to switch off and extinction of the fireplace 600sec Period Here one cans et the time from 100 to 1000 seconds in...

Page 17: ...Start Mode In this mode what happens is the so called initial clean which lasts 60 seconds by default The smoke fan is set on maximum speed to clean the ashtray If we would like we can change the tim...

Page 18: ...are on Modulation 5 on pressing the selection field it will redirect to Modulation Change Menu It is important to note that this change is permanent It is saved and on restarting the control unit and...

Page 19: ...pump Check sensors Clean check and remove all debris from the ignition system Clean and check the electronic control system Check all electrical cables Clean the pellet fuel hopper and check auger to...

Page 20: ...given icon Exhaust gases High temperature of the combustion chamber above380 0 To remove the alarm the temperature has to drop below this value The stove continues to work Exhaust gases High temperat...

Page 21: ...in accordance with current regulations and laws Operation Well dried and of good quality wood pellets Diameter of 6 mm and maximum moisture content of 8 Chimney connecting flue pipes and combustion ch...

Page 22: ...ellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another type of fuel leads to damage SPARE PARTS CATALOGUE Denomination Denomination 1 Gear motor for auger 17 Fire...

Page 23: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 23...

Page 24: ...Victoria 05 Ltd 24...

Page 25: ...internal contact with fire or hot surfaces Pellet stove is equipped with safety components that guarantee lock it automatically in case of failure of any of its components Safety components are activ...

Page 26: ...ease contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following cases Quickly worn out components glass...

Page 27: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 27 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Page 28: ...Victoria 05 Ltd 1BIvan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 E mail info v05 bg http www v05 bg...

Reviews: