02.2020
INSTRUCTION MANUAL
for installation and operation of pellet stove
VITTORIA В*
11
Circulation pump
The circulation pump is with a high efficiency for water heating systems with an integrated control of differential pressure.
Control modes:
Variable differential pressure (∆р-v)
Set value of differential pressure H varies within the acceptable range of flow between
1
2
Н
s
and Н
s
. Factory setting: ∆р-v,
1
2
Н
max.
Constant differential pressure (∆р-c)
In this mode of regulation is maintained constant set value of the differential pressure.
Venting function
The pump is vented automatically upon initial startup. If the pump is not vented automatically, select manual mode of venting
"air". The process starts in a few seconds and lasts up to 10 minutes. Select the desired mode of operation of the pump after
completion of venting.
10.Appliance operation.
10.1. Initial ignition.
The installer of the pellet stove should perform the initial release!
The installer is required:
- to verify that the installation is performed correctly and the expansion vessel
meets in size, ensuring safe operation.
- to check the dimensions of the connecting flue pipes and chimney;
- to switch on the power of the pellet stove and make "cold" test;
- to fill up the heating system with liquid through the inlet at pressures to 1.5
bar and make sure that there are no leaks;
- to ensure that all taps between the pellet stove and heating system are open;
- to bleed the system before starting (see Fig.3);
This operation must be repeated in the first days of use, and when the system is
recharged, even partially. The presence of air in the heating system can aggravate
proper
operation of the pellet stove. In order to facilitate venting, the appliance is equipped with plastic tubing that connects
to the air vent
- to set the pellet stove according to the type of wood pellets used;
- to carry out emission control of flue gases after installation;
- to make a detailed instruction of the user;
Pellet stove is coated by high temperature resistant paint, but not against corrosion. In case of accumulation of dust, surfaces
can be cleaned with a soft brush or a dry cloth, but in any case with a damp cloth or water.
Before the first ignition, remove the color label for energy efficiency from the glass of the pellet stove.
Upon initial ignition not place any objects on the pellet stove and do not touch the outer surface to avoid damaging the coating.
The flavor, which is obtained as a result of the drying of the paint, disappears after a few hours. Ventilate the room where is
located the pellet stove.
If as a result of overheating or due to incorrect operation color changes, appeared stain rust or damaged part of the coverage,
you can order spray paint in the color from your dealer.
Before ignition, check: power, door seal, if the combustion chamber is cleaned and whether the display is switched to
standby mode.
10.2. Control panel description.
After start up, on the control display is shown the logo of Victoria-05 for 3 seconds and then switches to main user panel. The
icons and functions are shown as follows:
H
H
max
H
s
1/2
H
s
H
min
Q
H
max
H
s
H
min
H