Victoria-05 Ltd.
10
А -Insulated metal chimney.
В – minimum height of the vertical section 1.5 m, as the end of the chimney has to be completed in accordance with Fig. 5
С -Incoming outside air through the section with minimum cross section of 80 сm
2
.
Е -Incoming outside air through the section with minimum cross section of 80 cm.
D -Metal pipe in masonry chimney.
Hydraulic connections:
The integral boiler of the pellet stove has a capacity of 22 liters. This volume ensures good and smooth operation of the
appliance and achieving maximum efficiency in heating.
Pellet stove MUST NEVER OPERATE without a liquid into the heating system and under pressure less than 1 bar.
Failure to comply with these conditions leads to damage!
INSTALATION HYDRAULIC DIAGRAM
A. Hot water outlet
B. Cold water inlet
1. Pellet stove with integral boiler
2. Control system
3. Closed expansion vessel 1.5 bar, 8l
4. Integral boiler
5. Manual air vent
6. Automatic air vent
7. Hydraulic safety valve 3 bar
8. Channel
9. Heat consumers
10. Three-way mixing valve thermostatic
11. Stopcock
12. Filter
13. Manometer 6 bar
14.Built-in circulation pump
The installation hydraulic diagram is indicative and does not replace the documentation for the construction of the
heating system made by an authorized person or company!
Trained and competent technicians must make hydraulic connections.
Allowed to be made and other inspections in accordance with applicable in that country national laws where pellet stove will be
installed and used.
Practical advice:
Take appropriate decisions when making connections for supply, return and drain the fluid in the heating system, which will
facilitate the removal of the pellet stove if necessary in the future;
Water treatment:
Consider adding fluids against freezing and corrosion. Use softener, if water in the system has the values of hardness higher than
19 dH.
Technician who installed the pellet stove should provide additional expansion vessel, depending on the type and
capacity of system that the device will serve.
It is obligatory installation of filter for incoming water. Failure to comply with this condition leads to FAILURE
WARRANTY of circulation pump!