            Picture 10                              Picture 11 
The amount of dust depends from the used fuel. 
Failure to do the cleaning procedure can cause the stove to block.  
After the cleaning procedure is completed, make sure that all service openings are closed and sealed properly. 
Seasonal maintenance (performed by the dealer): 
The dealer firstly is setting the amount of pellets consumed after which the message “Maiten??” appears on the 
display.  The stove is continuing normal operation, but the end client must contact the dealer to perform the 
necessary  seasonal  maintenance. 

The end client is  invited to  perform seasonal maintenance regardless of  which 

messages may appear on the display.

 

Before performing any maintenance procedure, disconnect the stove from the electric supply. 

-

 

Clean the stove outside and inside. 

-

 

Carefully clean the tubes of the heat exchanger. 

-

 

Carefully 

clean and remove dirt from the combustion chamber and the relative compartmen

t. 

-

 

Clean the motors, verify mechanical and clam loosening

-

 

Clean smoke channel (replace seals on pipes) and smoke extraction fan chamber

-

 

Check the expansion tank

-

 

Check and clean the circulator

-

 

Check the sensors

-

 

Check and if necessary replace the clock battery on the control board

-

 

Clean,  inspect  and  scrape  any  residue  from  the  ignition  resistance  compartment  and  if  necessary, 

replace it

-

 

Check and clean the control panel and display.  

-

 

Check all electric cables. 

-

 

Clean the pellet hopper and check loosening of the feed screw - gear motor assembly

-

 

Check and if needed replace the door seal. 

-

 

Make a functionality test: 

load the feed screw, ignite, let it run for 10 minutes and shutdown.

If the procedures for maintenance are not performed regularly, the warranty will void. 
If the stove is used very often it is recommended to clean the smoke channel once every 3 months. 
 

Warning!!! After completing cleaning procedure, inappropriate assemble (Picture 7) of the upper and lower 
part  of  the  combustion  chamber  can  result  a  drop  in  stoves  performance.  Make  sure  that  it  is  all  correct 
assembled before igniting. 

When cleaning procedure is  performed on the  smoke  ducts, consider the  regulations regarding the  individual 
chimneys for generators running on solid or liquid fuel. 
Maintenance and control: 
The chimney to which the stove is connected must be cleaned at least once per year (please check is there an 
additional regulation norm in your country). 
If regular check-ups and cleaning procedures are not performed, the risk of fire inside the chimney increases.  
If  such  a  fire  is  started,  do  the  following:  do  not  use  water;  empty  the  hopper  from  the  pellets;  contact  the 
dealer before reigniting.   

 

15.Possible troubleshooting 

If  there  is  a  problem,  the stove  will  automatically  stop  and  start  shutdown  procedure. The  display  shows  the 
reason for the shutdown (see the various alarms below). 
Never pull the plug for the electric supply during shutdown procedure!. 
When  there  is  an  event  of  malfunctioning.  To  restart  the  stove  it  is  necessary  to  wait  the  procedure  for 
shutdown to be completed (10 minutes with acoustic signal). 
Do  not  start  the  stove  before  checking  and  if  needed  solve  the  problem  for  the  stopping  and  clean  the 
combustion chamber. 

Possible reasons for blocking: Indication and solution. 

 

1

. H2O PTC_FAULT

Shuts down due to the water temperature sensor being broken or disconnected.

 

- Check connection of the sensor to the control board. Verify functionality by means of a “cold test”

 

Summary of Contents for Vittoria B Series

Page 1: ...1 Instruction for installation and operation of pellet burning stove with integral water boiler VITTORIA...

Page 2: ...nciple of operation 7 7 Operation 8 8 Safety and detection devices 8 9 Components 8 10 Installation 9 11 Basic instructions for use 11 12 Instructions for use 12 13 Operating modes 12 14 Maintenance 1...

Page 3: ...can be damaged if it is ignited or used with no water in the system The stove is designed to heat water by means of automatic combustion of pellets wood with 6 mm diameter in the combustion chamber If...

Page 4: ...tly and safely The stove must be kept in a room where the temperature is above 0 C Use appropriate anti freeze additives for the water of the system Ensure that the temperature of the return water is...

Page 5: ...s are calculated on the basis of pellets with an heating value of at least 4300 kcal kg and heating loss of the roomof 33 Kcal m h It is also important to consider the position of the stove in the roo...

Page 6: ...has to be reset manually Tank safety thermostat Switches off when the temperature in the stove is too high It stops pellet loading which is causing the stove to shut down It has to be reset manually...

Page 7: ...ing the tank is thru the back of the lid at the rear of the top The fuel pellets is taken from the tank A and via an Archimedes screw powered by electric gear motor is transported to the combustion ch...

Page 8: ...mocouple It is located at the smoke exhaust to measure the temperature It is also controlling the ignition and if the temperature is too high or too low it triggers shut down sequence Stop Flame Hoppe...

Page 9: ...ations in the voltage above 10 can cause malfunction in the appliance unless the appropriate differential switch is installed The electrical system should be in accordance with all local regulations a...

Page 10: ...d into a chimney flue a vertical section of at least 1 5 m will be required complete with a wind guard The vertical duct can be internal or external If the smoke channel is outside it must be insulate...

Page 11: ...ring the filling bleed the pump manually and open the manual vent Picture 3 These actions must be carried subsequently periodically 11 Basic instructions for use Command board Picture 5 1 Button turn...

Page 12: ...date set 12 Instructions for use Feeling the feed screw When the tank for pellets is completely empty this means that the feed screw is also empty Before re igniting the stove you must fill it up fol...

Page 13: ...on the display if is pressed No Prog Prog No 1 one ignition and shutdown per day Prog No2 same as before Prog No3 same as before Use the button to show them in reverse order If you choose the first pr...

Page 14: ...not performed and at least once a season don t make a complete cleaning could cause to poor functionality Any problems resulting from lack of maintenance will immediately void the warranty Daily maint...

Page 15: ...own If the procedures for maintenance are not performed regularly the warranty will void If the stove is used very often it is recommended to clean the smoke channel once every 3 months Warning After...

Page 16: ...rift 8 H2O TEMPALARM Shuts down due to water temperature being higher than 90 C An excessive temperature may occur because of the following system too small ask the DEALER to activate the ECO function...

Page 17: ...stove produce hot air NO Most of the heat is transferred by the water Only small part of the heat is transferred to the room whre the stove is installed by means of radiant heat from the glass It is r...

Page 18: ...18...

Page 19: ...19...

Page 20: ...not kept damages caused during transport inappropriate made heating calculations and project for heating system and installation of the stove there have been made changes in the construction of the st...

Page 21: ...21 Victoria 05 Ltd 61A Anton Strashimirov Str 5100 Gorna Oryahovitsa Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg...

Reviews: