When the stove is operational by pressing button 0/1 for 2 seconds, the process for shutting down the stove is 
started and OFF is displayed for 10 minutes. Shutdown phase includes: 
-

 

Pellet feeding is stopped. 

-

 

Stopping the circulation of the water.  

Never pull off the plug during shutdown process!  
Please have a note that the circulation pump will work till the temperature of the water drops under 40

o

C. 

 

Setting the clock: 
Press “MENU” button for 2 seconds and use +/- buttons to follow the instructions shown on the display. Access 
clock menu. This menu will allow you to change and set the time. After that press “MENU” and the following 
information will appear, and can be adjusted: day, month, year, hour, minutes, day of the week. When “Save?” 
appears, you can chesk  is everything entered correctly  before  confirming. Press “MENU” to confirm and save 
the information („Save OK „ is show on the display). 

 

Programming for igniting and shutting down of the stove at different time in the week. 
Press “MENU” for 2 seconds, to enter in time setting menu and press + button to enter in weekly timer function. 
“Program  ON  /OFF”  ще  will  appear  on  the  display.  This  timer  allows  you  to  set  number  of  ignitions  and 
shutdowns  per  day  (up to  three)  for each  day of the  week.  After  confirming with “MENU”  button one  of  the 
following options will appear: 
-

 

No Prog. (no program is set); 

-

 

Program/daily (a single program is set for every day) 

-

 

Program/weekly (a program is set for each day of the week.) 

 

You can change to every menu by pr/- buttons.  
Press “MENU” to confirm “Daily Program” and access to few programs (ignition/shutdown) to be set per day. 
Use Program/daily option to set the same program for each day of the week. 
The following will appear on the display if + is pressed: 
-

 

No Prog. 

-

 

Prog. No 1 (one ignition and shutdown per day) Prog. No2 (same as before) 

Prog. No3 (same as before) 
Use  the  button  to  show  them  in  reverse  order.  If  you  choose  the  first  program  the  time  of  ignition  will  be 
shown.  
The display shows: 1 ignition hour 10:30; use the +/- buttons to change the hour and press “MENU” to confirm. 
The  display shows: 1 ignition minutes 10:30  use  the +/-  buttons to change the minutes and press “MENU” to 
confirm 
Shutdown time is set by the same way.  
The programs are set and by pressing “MENU” button when “Save” is shown on the display.  
To confirm program Program/week you need to choose the day to which the program apply.  
1 Mon, 2 Tues, 3 Wed, 4 Thurs, 5 Fri, 6 Sat, 7 Sun 
When you have chosen the day by pr/- buttons, press “MENU” to confirm and continue with the settings 
in the same way as for Program/daily, 

selecting whether or not to enable a program for each day of the week 

and choosing the number and times of interventions.

 
If  you made  a mistake  during  programming  you  can exit  without  confirming  the  settings  by  pressing  0/1  and 
Save will be shown on the display. 
 
If the stove runs out of pellets the stove will block and Stop/Flame will be shown on the display. 
 
Pellet reserve warning. 
The  stove  is  equipped  with  electronic  system  to  monitor  the  pellets.  The  system  is  integrated  in  the  control 
module, which allows the stove to monitor how many pellets are left in the hopper. While the stove is working 
the check up is made constantly.  
For proper work of the system it is important to follow the procedures during first ignite (made by the dealer). 
Before  the system for monitoring start  working, you have  to load and use  full  stack of pellets. This will allow 
brief running of the loading system. Subsequently load 15 kg pellets. 
 
Then press once the “reserve” button to confirm and save in the memory that you have load 15 kg pellets in the 
hopper. 
 

Summary of Contents for Vittoria B Series

Page 1: ...1 Instruction for installation and operation of pellet burning stove with integral water boiler VITTORIA...

Page 2: ...nciple of operation 7 7 Operation 8 8 Safety and detection devices 8 9 Components 8 10 Installation 9 11 Basic instructions for use 11 12 Instructions for use 12 13 Operating modes 12 14 Maintenance 1...

Page 3: ...can be damaged if it is ignited or used with no water in the system The stove is designed to heat water by means of automatic combustion of pellets wood with 6 mm diameter in the combustion chamber If...

Page 4: ...tly and safely The stove must be kept in a room where the temperature is above 0 C Use appropriate anti freeze additives for the water of the system Ensure that the temperature of the return water is...

Page 5: ...s are calculated on the basis of pellets with an heating value of at least 4300 kcal kg and heating loss of the roomof 33 Kcal m h It is also important to consider the position of the stove in the roo...

Page 6: ...has to be reset manually Tank safety thermostat Switches off when the temperature in the stove is too high It stops pellet loading which is causing the stove to shut down It has to be reset manually...

Page 7: ...ing the tank is thru the back of the lid at the rear of the top The fuel pellets is taken from the tank A and via an Archimedes screw powered by electric gear motor is transported to the combustion ch...

Page 8: ...mocouple It is located at the smoke exhaust to measure the temperature It is also controlling the ignition and if the temperature is too high or too low it triggers shut down sequence Stop Flame Hoppe...

Page 9: ...ations in the voltage above 10 can cause malfunction in the appliance unless the appropriate differential switch is installed The electrical system should be in accordance with all local regulations a...

Page 10: ...d into a chimney flue a vertical section of at least 1 5 m will be required complete with a wind guard The vertical duct can be internal or external If the smoke channel is outside it must be insulate...

Page 11: ...ring the filling bleed the pump manually and open the manual vent Picture 3 These actions must be carried subsequently periodically 11 Basic instructions for use Command board Picture 5 1 Button turn...

Page 12: ...date set 12 Instructions for use Feeling the feed screw When the tank for pellets is completely empty this means that the feed screw is also empty Before re igniting the stove you must fill it up fol...

Page 13: ...on the display if is pressed No Prog Prog No 1 one ignition and shutdown per day Prog No2 same as before Prog No3 same as before Use the button to show them in reverse order If you choose the first pr...

Page 14: ...not performed and at least once a season don t make a complete cleaning could cause to poor functionality Any problems resulting from lack of maintenance will immediately void the warranty Daily maint...

Page 15: ...own If the procedures for maintenance are not performed regularly the warranty will void If the stove is used very often it is recommended to clean the smoke channel once every 3 months Warning After...

Page 16: ...rift 8 H2O TEMPALARM Shuts down due to water temperature being higher than 90 C An excessive temperature may occur because of the following system too small ask the DEALER to activate the ECO function...

Page 17: ...stove produce hot air NO Most of the heat is transferred by the water Only small part of the heat is transferred to the room whre the stove is installed by means of radiant heat from the glass It is r...

Page 18: ...18...

Page 19: ...19...

Page 20: ...not kept damages caused during transport inappropriate made heating calculations and project for heating system and installation of the stove there have been made changes in the construction of the st...

Page 21: ...21 Victoria 05 Ltd 61A Anton Strashimirov Str 5100 Gorna Oryahovitsa Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg...

Reviews: