background image

 

UG:402 

Page 7

The following is a list of all connectors and components present on the USB-ADAPTER-1V-B00 and 
USB-ADAPTER-4V-A00 Adapter Bridge Boards.

Reference

Designator

Description

Manufacturer

Manufacturer Part 
Number

R04, R05, R08

RES 0

Ω

 1/16W 1% 0402

KOA Speer

RK73Z1ETTP

R06

RES 1k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP1001F

R01

RES 10k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP1002F

R02

RES 1.05k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP1051F

C01

CAP X7R 0.1µF 10% 16V 0402

Murata

GRM155R71C104KA88D

D01

DLED RED SMD 0402

Panasonic

LNJ247W82RA

J01

CONN MICRO-B USB SMD

TE Connectivity

2174507-2

J02

CONN MICRO HDR 5POS 1.25mm 
SINGLE ROW RA

Molex

504195-0570

Reference

Designator

Description

Manufacturer

Manufacturer Part 
Number

R01

RES 0

Ω

 JUMPER 1A 0603

KOA Speer

RK73Z1JTTD

R06, R09

RES 0

Ω

 1/16W 1% 0402

KOA Speer

RK73Z1ETTP

R08

RES 1k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP1001F

R07

RES 10k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP1002F

R02

RES 1.05k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP1051F

R03

RES 2.8k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP2801F

R04

RES 3.92k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP3921F

R05

RES 5.23k

Ω

 1/16W 1% 0402

KOA Speer

RK73H1ETTP5231F

C01

CAP X7R 0.1µF 10% 16V 0402

Murata

GRM155R71C104KA88D

D01

DLED RED SMD 0402

Panasonic

LNJ247W82RA

J01

CONN MICRO-B USB SMD

TE Connectivity

2174507-2

J02, J03, J04, J05

CONN MICRO HDR 5POS 1.25mm 
SINGLE ROW RA

Molex

504195-0570

Table 2

 

USB-ADAPTER-1V-B00 

Components

Table 3

 

USB-ADAPTER-4V-A00 

Components

Summary of Contents for PowerBench PMBus

Page 1: ...s provided for users to easily monitor and control the power module The PMBus interface of a VIA a dedicated Digital Supervisor or Point of Load Isolator is used for communication purposes with the provided GUI installed on the user s PC The PMBus interface of a VIA Digital Supervisor or PLI allows users to read and write into the status configuration registers of the module monitor faults and obt...

Page 2: ...ct with hot surfaces n n Never use a jumper in place of the fuse n n When testing electronic products always use approved safety glasses Follow good laboratory practice and procedures n n Avoid creating ground loops when making measurements of the isolated input or output voltage and signals n n Care should be taken to protect the user from accidental contact when under power n n Care should be ta...

Page 3: ...GNAL RETURN Signal Ground 6 Chassis GND SHIELD Connector Housing Ground 6 Chassis GND VDDB SDA SCL SGND SGND Micro USB Connector 1 2 3 4 5 Side View VIA VIA VIA VIA Host PC and GUI Adapter Bridge Board USB ADAPTER 4V A00 VIA to Adapter Bridge Board Cable 43503 01 PMBus to USB Adapter I2C ADAPTER A00 ISOLATION BOUNDARY Figure 1 Host PC to VIA Power Module Array Connection PMBus Communication Interf...

Page 4: ...nnection to host PC n n Provides 5V external bias VDDB n n Isolated PMBus to host interface 4242VDC n n Measurement of input and output parameters including but not limited to n n Voltage n n Current n n Power n n Temperature n n Fault monitoring including but not limited to n n Overvoltage Undervoltage n n Overcurrent n n Overtemperature n n Enable Disable control Part Number Description USB ADAP...

Page 5: ... 1V B00 the VIA PMBus address is programmed to 51h by a pre installed resistor R02 On the Adapter Bridge Board USB ADAPTER 4V A00 the four VIA PMBus addresses are programmed to 51h 53h 54h 55h by pre installed resistors R02 R05 An LED provides visual indication that VDDB 5V is present Lastly the PMBus to USB Adapter connects to the user s computer where the provided Vicor Digital Interface Demo GU...

Page 6: ... Connector 3 2 1 4 5 J02 GND 0402 C01 0402 R06 0402 R02 0402 R07 D01 0402 R08 GND 0603 R01 VDDE VDDE VDDE ADDRESS_1 GND ADDRESS_1 0402 R03 ADDRESS_2 GND 0402 R04 ADDRESS_3 GND 0402 R05 ADDRESS_4 GND SDA SDA SCL SCL SGND SGND Micro Lock Connector 3 2 1 4 5 J03 VDDE ADDRESS_2 SDA SCL SGND Micro Lock Connector 3 2 1 4 5 J04 VDDE ADDRESS_3 SDA SCL SGND Micro Lock Connector 3 2 1 4 5 J05 VDDE ADDRESS_4...

Page 7: ...NGLE ROW RA Molex 504195 0570 Reference Designator Description Manufacturer Manufacturer Part Number R01 RES 0Ω JUMPER 1A 0603 KOA Speer RK73Z1JTTD R06 R09 RES 0Ω 1 16W 1 0402 KOA Speer RK73Z1ETTP R08 RES 1kΩ 1 16W 1 0402 KOA Speer RK73H1ETTP1001F R07 RES 10kΩ 1 16W 1 0402 KOA Speer RK73H1ETTP1002F R02 RES 1 05kΩ 1 16W 1 0402 KOA Speer RK73H1ETTP1051F R03 RES 2 8kΩ 1 16W 1 0402 KOA Speer RK73H1ETT...

Page 8: ...provide 5V VDDB from an external source 2 Power up module within operating range specified by the device datasheet 3 Open the Vicor Digital Interface Demo Board software installed on the connected host PC 4 Go to Tools Scan for Digital Supervisor to detect digital supervisor as shown in Figure 4 1 5 Go to Tools Scan for Devices and select desired power module device as shown in Figure 4 2 6 Verify...

Page 9: ... implement adequate design testing and operating safeguards for your planned application s and use s VICOR PRODUCTS ARE NOT DESIGNED AUTHORIZED OR WARRANTED FOR USE IN LIFE SUPPORT LIFE CRITICAL OR SAFETY CRITICAL SYSTEMS OR EQUIPMENT VICOR PRODUCTS ARE NOT CERTIFIED TO MEET ISO 13485 FOR USE IN MEDICAL EQUIPMENT NOR ISO TS16949 FOR USE IN AUTOMOTIVE APPLICATIONS OR OTHER SIMILAR MEDICAL AND AUTOM...