background image

Before operating this product, please read the instructions carefully and save this manual for future use.

Operating Instructions

Buildup Adapter

Model No.  

AK-HBA3500G

FRANÇAIS

DEUTSCH

ENGLISH

IT

ALIANO

ESP

AÑOL

РУССКИЙ

日本語

VQTB0295

Summary of Contents for AK-HBA3500G

Page 1: ...ing this product please read the instructions carefully and save this manual for future use Operating Instructions Buildup Adapter Model No AK HBA3500G FRANÇAIS DEUTSCH ENGLISH ITALIANO ESPAÑOL РУССКИЙ 日本語 VQTB0295 ...

Page 2: ...E EQUIPMENT CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that m...

Page 3: ...ing it to strong impact may cause malfunctioning and or accidents Operate the unit within a temperature range of 14 F 10 C to 113 F 45 C Be absolutely sure to turn off the power before connecting this unit to the buildup unit When using the unit in windy or snowy conditions or at the beach or at the waterfront cover it with the rain cover optional accessory or protect it in some other way in order...

Page 4: ...e viewfinder s interface connector For details on the specifications of this connector refer to the operating instructions of the AK HVF985B viewfinder 5Lock knob The knob is threaded inside Tighten it securely when the adapter has been mounted on the buildup unit Refer to page 4 6Buildup unit I F connector This is the interface connector of the buildup unit For details on the specifications of th...

Page 5: ...s for the lock base are not tightened up sufficiently the buildup adapter may teeter or even fall off after it has been mounted onto this base possibly resulting in injury Note 2 Remove the connector cap Keep this in a safe place to ensure that it will not be lost or misplaced 3 Align the guide pins large and small to mount the buildup adapter and turn the lock knob in the direction of the arrow a...

Page 6: ...nsure safety check that the buildup adapter is secured firmly by attempting to move it backward or forward Note 5 Slide the safety lever in the direction of the arrow Now check that its red mark is visible through the openings To ensure safety check that it will not reach the back even when the lock release lever is pressed Safety lever Lock release lever Openings ...

Page 7: ...uch a way that the V shaped edge of the pan base fits into the V shaped groove in the pan base support and that the protruding area of the pan base is positioned as shown in the figure V shaped edge Pan base Pan base support Viewfinder connector Protruding area 2 Push the grip away from you to firmly secure the viewfinder to the pan base support The camera and viewfinder are now connected through ...

Page 8: ... lever of the tripod If these levers are not secured the center of gravity will shift causing the tripod to topple over and possibly resulting in injury Note 1 Detach the viewfinder by first turning the release levers in the directions of arrows 1 and 2 and then lifting the viewfinder in the direction of arrow 3 Release levers ...

Page 9: ...while pressing the lock release lever in the direction of arrow 2 Safety lever Lock release lever Openings 3 Turn the lock knob in the direction of arrow 4 to disengage the mounting and pull up the buildup adapter in the direction of arrow 5 Lock knob 4 Attach the accessory connector cap to the buildup unit arrow 6 Connector cap Failure to attach the connector cap may result in electric shocks and...

Page 10: ... lens Buildup Unit AK HBU3500 Buildup Adapter AK HBA3500 8 LCD Viewfinder AK HVF931A Troubleshooting Symptom Cause and remedial action The viewfinder does not work Check that the viewfinder connector is connected Check that the I F connector of the buildup unit is connected Check that the power of the camera is on and that the viewfinder power switch VF POWER of the buildup unit is at the ON posit...

Page 11: ...10 E ENGLISH Appearance Unit Inch mm 11 279 7 1 16 180 5 5 8 143 ...

Page 12: ...C to 45 C Storage temperature 4 F to 140 F 20 C to 60 C Ambient operating humidity Less than 85 Dimensions W H D 11 5 5 8 7 1 16 279 143 180 mm Weight Approx 5 51 lbs 2 5 kg Weight and dimensions shown are approximate Specifications are subject to change without notice ...

Page 13: ...12 E ENGLISH Memo ...

Page 14: ...adcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m PST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Panasonic de Mexico S A de C V Av angel Urraza Num 1209 Col de Valle 03100 Mexico D F 52 1 951 2127 Panasonic Puerto Rico In...

Reviews: