Replacing a Bad Database Drive
When one of the RAID drive fails, the Shadow will beep to announce that a
drive has failed.
1. Log in to the Web Console as previously described.
2. The opening screen will indicate a Health Degraded message. Click
Connect.
3. The failed drive will be indicated in the drive list by a red mark and have
the indication (Foreign) next to the drive name.
4. The beep can be turned off by right clicking the Intel RAID Controller at
the top left side of the screen and selecting Silence Alarm.
5. Click on the drive to display a screen that indicates the slot number of
the bad disk.
Note
The drives are numbered starting at 0 going across to the right as 1, 2, 3; the
second row starts at the left as 4 and continues as 5, 6, 7.