SETTING
MENUS
1
DISPLAYINGTHE POWER LOSS LIST (POWER LOSS LIST)
Turn the JOG dial to select “POWER LOSS LIST”. Turn the SHUTTLE ring to the right to display the
Power Loss List. Power failure start times are stored in memory, so it is possible to confirm when
POWER
LIST CLEA
R
they have occurred. Up to 3 power failure start times will be displayed. If more than 3 failures have
ALARM LIST
occurred, the first and the last 2 power failure start times will be displayed.
2
DISPLAYINGTHE ALARM LIST (ALARM LIST)
Turn the JOG dial to select “ALARM LIST”. Turn the SHUTTLE ring to the right to display the Alarm List. Alarm record start
are stored in memory, so it is possible to confirm when they have occurred. Up to 3 alarm record start times will be displayed.
more than 3 alarm records have occurred, the first and the last 2 alarm record start times will be displayed.
3
INITIALIZING ALL MENU SETTINGS (ALL MENU INITIALIZE)
Turn the SHUTTLE ring to the right and “ALL MENU INITIALIZE” will be displayed. When the SHUTTLE ring is turned to
the left, each setting is initialized except the TIMER RECORDING setting. When the SHUTTLE ring is turned to the right,
the “MAINTENANCE” menu will be displayed.
4
POWER LOSS LIST CLEAR
Turn the SHUTTLE ring to the
LOSS LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the
left, the Power Loss List is cleared. When the SHUTTLE ring is turned to the right,
menu will be displayed.
5 ALARM LIST CLEAR
Turn the SHUTTLE ring to the right and
LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the left,
the alarm list is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.
T I M E S E T
D TAPE END
1
SETTING THE OPERATION WHEN THE TAPE REACHES THE END (TAPE END)
QUASI V-SYNC
Sets the state of operation of the VCR when the tape runs out during recording.
TAPE LENGTH
E-180
TIME DATE ADJUST
STOP:
The tape stops. “End” will appear on the fluorescent display and “Tape End” will appear
on the monitor. When “CALL OUT” is set to
END”, a CALL signal is output
from the CALL terminal.
REWIND: Rewinds the tape to the beginning and stops (except during timer recording.)
When “CALL OUT” is set to
END,” a CALL signal is output for 2 seconds from the CALL terminal.
REPEAT: Rewinds the tape to the beginning and resumes recording.
ALARM-PROT (ALARM PROTECTION): If alarm recordings are present on the tape, then the tape stops. “End” will appear on
the fluorescent display and
End” will display on the monitor. When “CALL OUT” is
set
END,” a CALL signal is output from the CALL terminal. If there are
no alarm recordings, the tape is rewound and recording continues.
2
SETTING QUASI-V-SYNC (QUASI V-SYNC)
Sets Quasi-V-Sync on or off.
ON:
Quasi-V-Sync signal is inserted on the video output signal when in the special
modes (still, slow motion,
reverse, fast
speed search) and during normal playback in
72H or 96H mode.
OFF:
Quasi-V-Sync signal is not inserted.
Some multiplexers may require the Quasi-V-sync OFF in order to work properly.
3
SETTING THE TAPE LENGTH (TAPE LENGTH)
Select
the tape length to function the tape remain indicator correctly.
E-l
When using E-180 tape
E-240: When using E-240 tape
4
THE PRESENTTIME, DATE AND DAYLIGHT SAVINGTIME
(TIME DATE ADJUST)
to the pages
2
I
3.