15
7.1 Computer Remote Control
The V5160MUX uses a very simple command set, each command consisting of three characters. The first
character in all cases is the slash or virgule (/). The unit looks only for a three -character command, with an initial
slash. It ignores all other characters. If a mistake is made in entering a command, just type in another slash
character followed by the appropriate character for the desired command. The commands are listed in the Table 2,
RS-232 Commands.
Signal Format is as follows:
1. Data Format: 1,200 Baud (Selectable)/ 8 Data Bit/No Parity/ One Stop Bit.
2. Mode: Half Duplex Mode (Not Echo Received Character).
RS-232 Pinout
Pin 1 Not Used
Pin 2 RS-232 In
Pin 3-4 Not Used
Pin 5 GND
Pin 6-9 Not Used
RS-232 Commands
COMMAND RS-232 CODE
Title /TI Numeric 01 /01
VCR /VR Numeric 02 /02
Rec View /RV Numeric 03 /03
Alarm /AM Numeric 04 /04
Menu /MU Numeric 05 /05
FRZ /FR Numeric 06 /06
Zoom /ZO Numeric 07 /07
Up /UP Numeric 08 /08
Down /DN Numeric 09 /09
Left /LF Numeric 10 /10
Right /RG Numeric 11 /11
Plus /PL Numeric 12 /12
Spot /SP Numeric 13 /13
Minus /MI Numeric 14 /14
SEQ /SQ Numeric 15 /15
Change /CN Numeric 16 /16
Enter /ET
Shift /SF
8. Maintenance
The V5160MUX Multiplexer unit requires no routine maintenance and is designed for long, trouble-free use under
normal operating conditions. Repair should only be attempted by qualified personnel.