background image

 

13 

5.9.2 Password Setup

 

Select 

PASSWORD SETUP

 on the 

SYSTEM SETUP

 menu and press 

(+)

 or 

(-) 

key to toggle the options:   

    DISABLE, ENABLE   

 
 
 
 
 
 
 

 
 
 
 

To enable a password, select “

ENABLE

”. 

Select 

NEW PASSWORD

 and press the 

ENTER 

key.  

Confirm password. 

Press the 

MENU

 key to exit programming screen . 

When the Password is forgotten, turn off the unit, press and hold 

TITLE

 key and turn the unit on again; the 

unit will now have a factory default settings.   

 
 

5.10  Factory Default Setting   

 
To return to the factory default setting, turn the unit off, press and hold the 

TITLE

 key and then turn the unit on 

again.   
 
 

6.  Operation 

 

Front panel LEDs light to indicate video inputs. Any channel without a video input is automatically skipped during 
sequencing. Refer to Table 1 for operation keys. 

In VCR playback, if no video was recorded, if a camera was not in  the  schedule to be recorded, or if there was 
video loss, the word  “Mask” appears on the screen.   

Record check function in VCR mode 

Press the 

VCR

 button to check the recording screen in VCR mode. Press 

VCR

 again to exit VCR mode. Press 

the  SEQ button to change to full screen sequencing. 

Full Real -Time Display in Multi-Screen mode   

Various multi-screen displays are available with full real-time displays in different split screen mode.   
Press Shift with numeric key to call each split mode.   
 
Use 

CHANGE

 key to select a window in the split screen and press a numeric key to insert that camera into the 

selected window.   
 
Group A (ch1~ch8 display for splits less than 9 displays) 
Shift Key + Numeric 1 : Quad display   
Shift Key + Numeric 2 : 6 screen display   
Shift Key + Numeric 3 : 8 screen display   
Shift Key + Numeric 4 : 7 screen display   
Shift Key + Numeric 5 : 9 screen display   
Shift Key + Numeric 6 : 10 screen display   
Shift Key + Numeric 7 : 13 screen display   
Shift Key + Numeric 8 : 16 screen display   
 
Group B (ch9 ~ch16  display for splits less than 9 displays)   
Shift Key + Numeric 9   : Quad display   
Shift Key + Numeric 10 : 6 screen display   

 

PASSWORD SETUP  

 PASSWORD   : DISABLE   

     NEW PASSWORD: _ _ _ _   

Summary of Contents for V5160MUX

Page 1: ...ce Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116...

Page 2: ......

Page 3: ......

Page 4: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Page 5: ...unting of the video product should follow Vicon s instructions and a mounting accessory recommended by Vicon should be used 9 Ventilation Slots and openings in the cabinet are provided for ventilation...

Page 6: ...ords as this can result in a risk of fire or electric shock 17 Object and Liquid Entry Never push objects of any kind into this video product through openings as they may touch dangerous voltage point...

Page 7: ......

Page 8: ...7 5 4 7 Trig Out 7 5 5 Record Setup 7 5 5 1 Field Delay Setup 8 5 5 2 Record Mode Setup 8 5 5 3 Alarm Record Setup 8 5 5 4 Alarm Speed Setup 8 5 5 5 VCR Input Setup 8 5 5 6 Zone Setup 8 5 5 7 Holiday...

Page 9: ...attempting installation 3 Description The V5160MUX Digital Color Multiplexer provides on screen display of sixteen camera inputs combined with numerous additional functions The image display is updat...

Page 10: ...tions selects entries SPOT Sets the Spot monitor analog screen Scrolls downwards through program selections selects entries SEQ Selects the sequential switching function Shifts cursor to the left in m...

Page 11: ...y and multi screen l Select TIME DATEand press the ENTER key The following menu is displayed 5 1 1 Date Format l Press the and keys to toggle between the formats The options are MM DD YEAR DD MM YEAR...

Page 12: ...as recorded on 5 3 Dwell Setup This menu allows you to adjust the dwell times of the 16 camera video displays l Select DWELL SETUP and press the ENTER key The following menu is displayed l Press the a...

Page 13: ...alarm on or off for each video channel ALARM POLARITY function enables you to define how the alarm is generated for each alarm input either normally open NO or normally closed NC contacts l Select ALA...

Page 14: ...an audible alarm l Select BUZZEROUT on the ALARMSETUP screen ON or OFF is highlighted l Press the and key to toggle ON or OFF l Press the MENU key to exit screen 5 4 6 Relay Out The RELAYOUT function...

Page 15: ...ains as set on the RECMODE time lapse or real time EXCLUSIVE Only alarmed camera records INTERLEAVE Alarm camera is interleaved into the pattern more often l Press the MENU key to exit screen 5 5 4 Al...

Page 16: ...ey to exit screen 5 5 7 Holiday Setup l Select HOLIDAY SETUP to designate holidays to be recognized as weekend for the recording option Press ENTER key The following screen is displayed l Select INSER...

Page 17: ...ill not display time title while TITLE key is pressed OFF ALWAYS Time Title never displays ON BY TITLE KEY Displays the characters of time title while TITLE key is pressed ON ALWAYS Time Title always...

Page 18: ...ETUP screen The option is highlighted l Press the and keys to toggle TOP or BOTTOM l Press the MENU to exit screen 5 8 Event Log The multiplexer keeps a record of the events up to 450 events by Power...

Page 19: ...4800 bps 9600 bps 19600 bps 38400 bps l Select UNIT ADDRESS to designate the address of the unit by pressing or key The addresses available are from 00 99 only for RS 485 l Select COMMUNICATION to ch...

Page 20: ...ord Mask appears on the screen Record check function in VCR mode Press the VCR button to check the recording screen in VCR mode Press VCR again to exit VCR mode Press the SEQ button to change to full...

Page 21: ...not recognize Video Loss as an alarm condition REC OUT Trigger Operation Mode When an alarm occurs this signals the VCR to record Trigger connection on rear panel of V5160MUX Alarm In Out Pin No Signa...

Page 22: ...top Bit 2 Mode Half Duplex Mode Not Echo Received Character RS 232 Pinout Pin 1 Not Used Pin 2 RS 232 In Pin 3 4 Not Used Pin 5 GND Pin 6 9 Not Used RS 232 Commands COMMAND RS 232 CODE Title TI Numeri...

Page 23: ...tries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company...

Page 24: ...pe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 71...

Reviews: