Installation: AURORA/VCR ONLY
XX090-02-00 Rev 1102 System Console
Installation: AURORA/VCR ONLY
Make connections as shown in the figure and tables below. Refer to the Reference chapter for cable
recommendations.
250V SB
2A 10-12VAC
RISK OF FIRE REPLACE
FUSE AS MARKED
CAUTION
PWR/COMM
JOYSTICK
RS232/RS485
AUX
CONTROL OUT
+ AC –
1
Connect the appropriate power
supply to this connector:
V1400X-PS for 120 VAC
V1400X-PS-230 for 230 VAC.
Connect to
V1400X-DJT or
V1400X-JST.
This connector not
used in AurorA/VCR
Only mode.
This connector is not
used in AurorA/VCR
Only mode.
For A99 Protocol: Connect to MIU(s)
to use VCRs and/or AurorA99/AurorA
multiplexers.
For A2000 Protocol: Connect directly
to RS-485 devices using Vicon's
AurorANet protocol. Note that the
V800MIU-3 uses AurorANet protocol
and must be used to connect to
AurorA99/AurorA multiplexers and
VCRs.
Note: You must choose A2000 or A99
protocol during programming. You
may not mix both protocols on one
system console.
*
*
Connect to RS-485* or RS-232
device(s). Connect to auxiliary
devices.
Pin No.
RS-485
RS-232
Signal Name
RS485 + (A)
RS485 – (B)
Ground
1
6
7
Pin No.
Auxiliary Devices
Signal Name
Ground
Aux 1
Aux 2
7
8
9
Pin No.
Signal Name
TxD
RxD
RTS
CTS
Ground
2
3
4
5
7
RS232
RS485
AUX
System Console "RS232,
RS485, AUX" Connector.
SYSTEM CONSOLE REAR PANEL
8000-8595-00-00
8002-9338-00-00
8000-8594-05-00
8004-8526-01
Figure 4
AURORA/VCR ONLY Installation