RECEIVERS
RECEIVERS DAISY-CHAINED TO CPU
DAISY-CHAIN
F R O M
STAR
OF RECEIVERS USING
Figure 8
Sample Star and Daisy-Chain Receiver Configurations
Note:
you have both NOVA and
receivers your sysfem, make sure
each receiver has a
unique address. NOVA receiver addresses are
by a
at the receiver and Vicoax
addresses are
the video
the
1 .
Route the cable chosen in
Cab/e
from the receiver or distribution line control. The
receiver/distribution line control-end of the cable will be connected per the instruction manual for that unit.
2 .
Select the following from the accessory kit:
l
connector
.
outer shield
.
inner shield
l
ferrule
.
six contact pins.
3 .
Slip the ferrule over the end of the cable. Refer to Figure 5b on page 13.
4 .
Using wire strippers, remove approximately 1.5 in. (3.8 cm) of outer insulation and shielding from the
cable.
5 .
Using wire strippers, remove approximately 0.25 in. (0.64 cm) of insulation from each of the conductor
wires.
6 .
Using a crimping tool, attach a contact pin to each of the six conductor wires.
7 .
If connections have already been made at the receiver or distribution line control-end of the cable, perform
step 8. If connections have not been made at the receiver/distribution line control-end of the cable,
perform step 9.
8 .
A chart containing the color of the conductor wires and the connection made with each conductor wire
should have been created at the time of receiver or distribution line control installation. If this chart does
X826 Rev 798 NOVA V1422
Installation 17