10
••••
Installation
XX128-02-00 Rev 904 Kollector Pro Network Digital Video Recorder
2. Connect the sensor wires to the SENS and GND connectors (refer to Figure 3-3 below).
3. Install the other end of this cable into the appropriate sensor output (NO or NC dry contact).
4. Connect the RJ45 cable to the appropriate channel in the rear panel (refer to Figure 3-2 on page 6).
RJ45 Cable
Termination Box
RJ45 Cable
Termination Box
Figure 3-3: Termination Box
5. When using a detector that operates with a resistor, the resistor should be connected as follows:
•
=
Normally Open Detector
: The resistor should be connected to the sensor (
SENS
) and the ground
(
GND
) connectors.
•
=
Normally Closed Detector
: The resistor should be connected between the detector's wire and the
ground (GND) connector.
NOTE:
16 1K
Ω
resistors are included.
Normally Open
Normally Closed
Normally Open
Normally Closed
Figure 3-4: Resistor Connection Types
Summary of Contents for Kollector Pro