XX128-02-00 Rev 904 Kollector Pro Network Digital Video Recorder
Installation
••••
7
•
=
Network Port:
A standard RJ-45 connector used to connect to a LAN/WAN.
•
=
VGA Monitor Output:
Used for digital video output to a monitor.
•
=
Auxiliary Fan:
Used to cool the unit during operation (available on 240 FPS models only).
NOTE:
Connector locations may vary according to KP type.
Mounting
There are two types of mounting recommended for the recorder, either desktop or rack. For more details,
refer to the Kollector Pre-installation Manual, XX128-7X.
Desktop
The desk or table must provide a surface of suitable strength for the Kollector Pro’s weight of 45 lb (20.5 kg).
In addition, there must be area left around the cabinet to provide suitable airflow for cooling. Do not place
heavy items on the cover.
Rack
The recorder was designed to be mounted in a standard 19-inch (483mm) wide vertical rack. Use the
provided rack mount ears to connect the recorder to the rack using hardware provided with the rack.
It is recommended that at least ¼ standard rack height of space be left in between multiple recorders
mounted in the same rack for cooling purposes.
WARNING
: Failure to leave space for cooling between recorders may result in malfunctioning and
possible failure of the recorder.