Chapter 5
Using LTE/LTE-A FDD Analyzer
Conducting modulation measurement
SPA06MA-O User’s Guide
April 2021
22145360, R005
Page 99
4
Optional.
Tap
Physical Cell ID
and select the type
Manual
or
Auto
.
–
Auto
lets the instrument detect the Physical Cell ID for the LTE signal auto
-
matically.
–
Manual
sets a specific Physical Cell ID for the LTE signal manually in order to
speed up with the synchronization with a BTS.
5
Optional.
Tap CFI and select the type
Manual
or
Auto
.
–
Auto
lets the instrument set the number of OFDM symbols used for transmit
-
ting PDCCHs in a subframe.
–
Manual
sets the number of OFDM symbols manually.
6
Optional.
Tap
PHICH Ng
to set the number of PHICH groups (Ng):
1/6
,
1/2
,
1
,
2
,
E-1/6
,
E-1/2
,
E-1
, or
E-2
.
7
Tap
Event Hold
and select
On
or
Off
to enable or disable the event hold
feature.When enabled, the display line for the PDSCH threshold appears
.
When
an event occurs, the measurement is put on hold until you tap the
Hold
icon on
the side bar.
8
Optional.
Tap
Miscellaneous
under
Menu
to do the following as needed.
a
To select the number of antenna ports, tap the
MIMO
and select
2x2
or
4x4
.
b
To assign an antenna port number automatically or manually, tap
Menu
>
Antenna Port
and select the options from
Auto
,
Antenna 0
,
Antenna 1
,
Antenna 2
, or
Antenna 3
.
If the MIMO is set to 2x2, the antenna ports 2 and 3 are disabled.
c
To turn the Multimedia Broadcast Multicast Service (
MBMS
) feature on or off,
tap
MBMS
and select
On
or
Off
. For proper MBMS testing, you need to set
the
Subframe Number
in the upper right screen with the same PMCH
subframe number.
d
To set the Multicast Broadcast Single Frequency Network (
MBSFN
) detection
automatically or manually for MBMS testing, tap
MBSFN
and select
Auto
or
Manual
.
An automatically detected or manually entered MBSFN ID appears on the
screen.
e
To select the Cyclic Prefix, tap
Cyclic Prefix
and select
Normal
or
Extended
.
f
To set the threshold for PDSCH, tap
PDSCH Threshold
and enter a value by
using the on-screen keyboard.
g
Tap
PDSCH Modulation Type
, and then select the modulation type option:
Auto, QPSK, 16 QAM, 64 QAM, 256 QAM, E-TM3.3, E-TM3.2, E-TM3.1a,
E-TM3.1, E-TM2a, E-TM2, E-TM1.2 or E-TM1.1
NOTE
The set of OFDM symbols that can be used for PDCCH in a subframe is given
by
0
,
2
,
3
or
4
in 1.4 MHz bandwidth and
1
,
2
or
3
in another bandwidth.
Summary of Contents for SPA06MA
Page 1: ...SPA06MA O User s Guide R005 ...
Page 2: ......
Page 22: ...Chapter 1 Overview Module installation SPA06MA O User s Guide Page 6 22145360 R005 April 2021 ...
Page 410: ...Appendix A Physical specifications SPA06MA O User s Guide Page 394 22145360 R005 April 2021 ...
Page 412: ...SPA06MA O User s Guide 22145360 R005 April 2021 English ...