Remote Commands
SCPI Commands Command Tables
MAP-200 Optical Switch mOSW-C1 Installation and User Guide
Standard
June 2016
Document Number 22112369-120 R000
Page 47
Common Commands
The following table lists common commands of the mOSW-C1 cassette
Command
Parameters
Output
Description
:SYSTem
:ERRor?
<err id>,
<description>
Extracts the first error code of the error
queue
:BUSY?
<state>
Query the busy state of the card
:RESet
Reset the cassette to its default state.
:TEST?
<test result>
Perform a self test.
:CONFig?
<dev> <type>
<maxin>…
Query configuration of all devices
:INFOrmation?
<serial> <part>
<firmware rev>…
Query card information
:LOCK
<state>,
<owner>, <ipid>
Lock the specified application for the
exclusive use of the owner.
:LOCK?
<state>,<owner>,
<ipid>
Query the lock status of an application.
:LOCK
:RELEase
Release the lock of an application
:DEVice
:INFOrmation?
<dev>
<dev info>
Query the device description
:FAULt
:SLOT?
<register>
Query fault register
:DEVice?
<dev>
<register>
Query fault register of device
:STATus
:DEVice?
<dev>
<register>
Query status register of device
:RESet
<dev>
Reset status register of devicer