Specifications
mOSW-C1 Parameters
MAP-200 Optical Switch mOSW-C1 Installation and User Guide
Standard
June 2016
Document Number 22112369-120 R000
Page 97
Parameter
1x2
2x2
Multi Mode (MM)
-55 dB
Optical Power
Max input power (optical)
300 mW
Lifetime
Lifetime
100 million
Switching time
Single Mode
Multimode
Electro-Mechanical (break to
make)
4 ms
210 ms
Settling time for 90% final IL
2 ms
60 ms
Settling time for 99% final IL
4 ms
90 ms
Environment
Operation temperature
0 – 50 °C,
Operation humidity
15 to 80% RH,
0 to 40 °C non condensing
Storage temperature & Humidity
-30 to 60 °C, non condensing
Physical
Dimensions (W x H x D)
4.1 x 13.3 x 37.0 cm
Weight
1.75 kg (with single slot pigtails)