![Viatron KNX IR Linker Manual Download Page 10](http://html.mh-extra.com/html/viatron/knx-ir-linker/knx-ir-linker_manual_1011668010.webp)
Seite 10 von 22
5.2
Scene building Implementation KNX to IR
Object
Title
Function
Data Ttype
2
Teaching/Activate KNX to IR
Scene
18.001
SceneControl
The communication object 2 has a total of 64 memory locations. These memory
locations are used by the KNX IR linker to store and transmit IR signals.
The communication object can emit a previously learned IR signal by receiving a KNX
telegram. Here, all 64 storage locations of the communication object 2 can be used.
5.3
String Output
Object
Title
Function
Data Type
5
String Output
String
16.000 String
This communication object is used for the output of strings on the building bus.
Messages about the status of the KNX IR linker are emited. The following scale shows
which strings are emited and their meaning.
.
String
Description
IR
[Number]
saved
The received IR code was assigned to the desired scene number
IR [Number] send The IR code of the desired scene number, was sent
No IR-Code
During transmission, there is no IR code under the desired scene
number
ERR: Learn
An error occurred during the learning process
ERR: Save
An error occurred during the memory process
IR [Nummer] hold The IR code for the scene with the number [number] has been
received
IR
[Nummer]
release
The IR code for the scene with the number [number] has been
reset
IR
[Nummer]
pulse
The IR code for the scene with the number [number] has been
received
No KNX Cmd
The received IR code is not stored under a scene
not available
This scene number is not available
IR not found
IR Code not found