Viatron GmbH –
Manual
KNX IR Linker
Page 1: ...Viatron GmbH Manual KNX IR Linker ...
Page 2: ...ON OFF 11 5 5 Dimmer module 2 button operation 12 5 6 Dimmer module 1 button operation 12 5 7 Blind module 2 button operation 13 6 Teaching and sending IR signals 14 6 1 Teaching and storing an IR signal 14 6 2 IR signal triggers KNX command 15 6 3 KNX command initiates transmission of an IR Signal 15 7 Installation of the device 16 8 Technical Specifications 17 8 1 Data sheet 17 8 2 System and er...
Page 3: ...use of this documentation and assumes no liability or guarantee with regard to accuracy completeness and currency of the given information Copyright 2017 Viatron GmbH Deutschland All rights reserved Texts images and graphics are subject to the protection of copyright and other laws for the protection of intellectual property No use even excerpts is permitted without express written consent This ap...
Page 4: ...Seite 4 von 22 List of abbreviations Abbreviation Explanations IR Infrared ...
Page 5: ...he building bus system KNX so that the control can be carried out via installed switch programs visualization A KNX telegram can effect the following on the KNX IR linker Teaching storing an IR signal Sending an IR signal Furthermore a KNX telegram can be sent by receiving a learned stored IR signal The device is operated via KNX telegrams Different device states are indicated by status LEDs on th...
Page 6: ...Seite 6 von 22 2 Block diagram 2 1 Schema KNX IR Linker Figure 1 Schematic KNX IR linker KNX IR Linker IR Signal KNX telegrams IR Signal Various KNX devices Various KNX devices KNX telegrams ...
Page 7: ...n Figure 2 Back of the unit 3 1 KNX Port The connection to the KNX bus system is carried out via screw terminals of type Weidmüller BL 5 08 02 180 SN OR BX The screw clamp is included in the delivery The power consumption of the KNX connection is indicated in the data sheet 4 Display of the front panel Figure 3 Front of the unit LEDs display various statuses for the user These can be taken from th...
Page 8: ...lowing table This makes it possible to control the following data point types via already taught in IR signals 1 001 Switch 3 007 Dimmer 1 008 Up Down The following scale shows which data point is assigned to which memory location Speicherplatz Objektnummer Datenpunkttyp Typ Funktion 1 10 1 001 Schalt1 Toggle 2 12 1 001 Schalt2 Toggle 3 14 1 001 Schalt3 Toggle 4 16 1 001 Schalt4 Toggle 5 18 1 001 ...
Page 9: ...e Increase Toggle 34 80 1 008 Jal 1 Up 35 Move Up Down Down 36 82 1 008 Jal 2 Up 37 Move Up Down Down 38 84 1 008 Jal 3 Up 39 Move Up Down Down 40 86 1 008 Jal 4 Up 41 Move Up Down Down 42 88 1 008 Jal 5 Up 43 Move Up Down Down 44 90 1 008 Jal 6 Up 45 Move Up Down Down 46 92 1 008 Jal 7 Up 47 Move Up Down Down 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 The free space is reserved for future...
Page 10: ...e status of the KNX IR linker are emited The following scale shows which strings are emited and their meaning String Description IR Number saved The received IR code was assigned to the desired scene number IR Number send The IR code of the desired scene number was sent No IR Code During transmission there is no IR code under the desired scene number ERR Learn An error occurred during the learning...
Page 11: ...lt7 Toggle 23 Status7 Status 24 7 Schalt8 Toggle 25 Status8 Status 26 8 Schalt9 Toggle 27 Status9 Status 28 9 Schalt10 Toggle 29 Status10 Status 30 10 Schalt11 Toggle 31 Status11 Status 32 11 Schalt12 Toggle 33 Status12 Status 34 12 Schalt13 Toggle 35 Status13 Status 36 13 Schalt14 Toggle 37 Status14 Status 38 14 Schalt15 Toggle 39 Status15 Status 40 15 Schalt16 Toggle 41 Status16 Status 42 16 Sch...
Page 12: ...R signal is received the KNX IR linker automatically sends the stop command If an IR signal is received at short notice the respective switch function for this dimmer is executed ON or OFF 5 6 Dimmer module 1 button operation Object Scene Number Title Function 68 31 Dim5 Increase Decrease 69 Switch_Dim5 Toggel 70 32 Dim6 Increase Decrease 71 Switch_Dim6 Toggel 72 33 Dim7 Increase Decrease 73 Switc...
Page 13: ...6 Up Down 92 46 Jal7 Move Up 47 Move Down 93 Lamellen7 Up Down If a stored IR signal is received at the KNX IR linker and a blind function is assigned to it the corresponding communication object is executed The following options are available for operating the blinds If an IR signal is received for more than 2 seconds the blind is lowered or raised until an IR signal has been received again or th...
Page 14: ...r sends the KNX command to activate the teach in process via the KNX bus For this purpose the scene building block communication object 1 or 2 is addressed with the corresponding storage location number The operating mode is learn 2 As soon as the KNX IR linker has received the command the Receive LED is lit Thus the KNX IR linker signals that it is in the learn state and waits for an IR signal fo...
Page 15: ...r the corresponding scene 6 3 KNX command initiates transmission of an IR Signal This is only possible with the scene module KNX to IR Figure 5 Scheme KNX command for sending an IR signal 1 The user sends the KNX command to activate the transmission process via the KNX bus 2 If a stored IR signal is found for this command the Send LED flashes and the KNX IR linker transmits the stored IR code of t...
Page 16: ...this case disturbing influences such as for example sun radiation have to be noticed and minimized The KNX IR Linker requires a KNX bus connection for the supply Programming key and LED as well as interfaces are only accessible from the rear panel If possible load physical address and application software into the device before setting it up ...
Page 17: ...IR Linker power supply KNX bus voltage ambient temperature 0 C bis 45 C current consumption KNX Bus max 10mA IR transmission range up to 7m Free view frontal standard receiver protection IP30 according to DIN EN 60529 weight 0 5Kg dimensions L W H 119 5 89 50 attachment free installation ...
Page 18: ... LED is on Operating voltage is applied KNX IR Linker ready for operation Receive LED is lit The KNX IR linker is in the learn state and waits for an IR signal to save it Receive LED changes from continuous to flashing During the learn process a valid IR signal was received and stored Receive LED flashes The KNX IR linker has received an IR signal which has been learned in advance Send LED flashes...
Page 19: ...re Never use caustic agents or solvents for cleaning The device can be cleaned with a dry cloth from the outside Otherwise the device is maintenance free No repairs may be carried out in case of damage for example by transport or storage ...
Page 20: ... time without prior notice Installation and assembly of electrical devices may only be carried out by a qualified electrician It is essential to observe the applicable accident prevention regulations Failure to observe the installation instructions may result in damage to the unit itself fire or other hazards This manual is part of the product and must remain with the end customer 10 2 Intended us...
Page 21: ...n NoName und viele weitere japanische Hersteller NETBOX Netbox NIKON NIKON NUBERT Nubert z B Subwoofer System ORTEK Ortek Hama PANASONIC PANASONIC Beamer PENTAX PENTAX NEU RC5 Philips und andere europäische Hersteller RC6A Philips Kathrein und andere Hersteller z B XBOX RC6 Philips und andere europäische Hersteller RCCAR RC Car IR Fernbedienung für Modellfahrzeuge RECS80 Philips Nokia Thomson Nord...
Page 22: ...Seite 22 von 22 11 Contact Viatron GmbH Carl Metz Str 3 76275 Ettlingen Tel 49 7243 5148 370 Fax 49 7243 5148 351 Email info viatron de For more information www viatron de ...