43
Parameter
Description
Units
Set by the
manufacturer
Range
Resolution
P 171
Feeder Y1 hard coal – 4 sect.
[s]
107
70 … 130
1
Feeder Y1 hard coal – 5 sect.
[s]
90
50 … 140
1
Feeder Y1 hard coal – 6 sect.
[s]
75
40 … 140
1
Feeder Y1 hard coal – 7 sect.
[s]
60
30 … 140
1
P 172
Feeder X2 hard coal
[%]
33
33
0
P 173
Feeder Y2 hard coal – 4 sect.
[s]
59
32 … 90
1
Feeder Y2 hard coal – 5 sect.
[s]
54
30 … 90
1
Feeder Y2 hard coal – 6 sect.
[s]
48
25 … 90
1
Feeder Y2 hard coal – 7 sect.
[s]
36
20 … 90
1
P 174
Feeder X3 hard coal
[%]
66
66
0
P 175
Feeder Y3 hard coal – 4 sect.
[s]
42
27 … 67
1
Feeder Y3 hard coal – 5 sect.
[s]
37
20 … 90
1
Feeder Y3 hard coal – 6 sect.
[s]
31
15 … 90
1
Feeder Y3 hard coal – 7 sect.
[s]
20
10 … 90
1
P 176
Feeder X4 hard coal
[%]
100
100
0
P 177
Feeder Y4 hard coal – 4 sect.
[s]
31
23 … 60
1
Feeder Y4 hard coal – 5 sect.
[s]
26
15 … 90
1
Feeder Y4 hard coal – 6 sect.
[s]
20
10 … 90
1
Feeder Y4 hard coal – 7 sect.
[s]
14
8 … 90
1
P 178
Feeder runtime in the attenuation – hard
coal
[s]
10
3 … 20
1
P 179
Standstill time(delay) feeder in the
attenuation – hard coal
[min.]
40
10 … 240
1
P 200
Ventilator X1 hard coal
[%]
0
0
0
P 201
Ventilator Y1 hard coal – 4 sect.
[%]
16
15 … 53
1
Ventilator Y1 hard coal – 5 sect.
[%]
17
5 … 60
1
Ventilator Y1 hard coal – 6 sect.
[%]
16
5 … 60
1
Ventilator Y1 hard coal – 7 sect.
[%]
28
5 … 80
1
P 202
Ventilator X2 hard coal
[%]
33
33
0
P 203
Ventilator Y2 hard coal – 4 sect.
[%]
22
18 … 59
1
Ventilator Y2 hard coal – 5 sect.
[%]
21
5 … 80
1
Ventilator Y2 hard coal – 6 sect.
[%]
20
5 … 80
1
Ventilator Y2 hard coal – 7 sect.
[%]
38
5 … 90
1
P 204
Ventilator X3 hard coal
[%]
66
66
0
P 205
Ventilator Y3 hard coal – 4 sect.
[%]
38
20 … 80
1
Ventilator Y3 hard coal – 5 sect.
[%]
37
15 … 80
1
Ventilator Y3 hard coal – 6 sect.
[%]
36
15 … 80
1
Ventilator Y3 hard coal – 7 sect.
[%]
50
20 … 90
1
P 206
Ventilator X4 hard coal
[%]
100
100
0
P 207
Ventilator Y4 hard coal – 4 sect.
[%]
51
30 … 90
1
Ventilator Y4 hard coal – 5 sect.
[%]
48
30 … 90
1
Ventilator Y4 hard coal – 6 sect.
[%]
47
30 … 90
1
Ventilator Y4 hard coal – 7 sect.
[%]
64
30 … 90
1
P 208
Ventilator slowing-down in the attenuation
regime– hard coal
[s]
90
5 … 200
1
P 209
Ventilator output in the attenuation – hard
coal
[%]
50
10 … 100
1
P 210
Feeder X1 pellets
[%]
0
0
0
P 211
Feeder Y1 pellets – 4 sect.
[s]
58
48 … 70
1
Feeder Y1 pellets – 5 sect.
[s]
50
20 … 80
1
Feeder Y1 pellets – 6 sect.
[s]
43
20 … 80
1
Feeder Y1 pellets – 7 sect.
[s]
36
15 … 80
1
P 212
Feeder X2 pellets
[%]
33
33
0
P 213
Feeder Y2 pellets – 4 sect.
[s]
28
18 … 40
1
Feeder Y2 pellets – 5 sect.
[s]
25
15 … 70
1
Feeder Y2 pellets – 6 sect.
[s]
21
15 … 70
1
Feeder Y2 pellets – 7 sect.
[s]
18
15 … 70
1
P 214
Feeder X3 pellets
[%]
66
66
0
P 215
Feeder Y3 pellets – 4 sect.
[s]
18
8 … 30
1
Feeder Y3 pellets – 5 sect.
[s]
16
8 … 50
1
Feeder Y3 pellets – 6 sect.
[s]
14
8 … 50
1
Feeder Y3 pellets – 7 sect.
[s]
12
8 … 50
1