background image

 

4

 

User’s operating instructions  

 

OPERATING INSTRUCTIONS  

6.1 

CONTROL PANEL  

 

 

 

A = Domestic hot water temperature control  
B = Summer/winter se Central heating temperature control knob  
C = Power On indicator led (Green)  
D = Central heating mode indicator led  
E = Burner On indicator led (Green) 

 

F = Not active  
G = Reset /chimneysweeper mode key  
H = Lock-out led indicator (Red)  
I = System temperature control/pressure gauge 
 
 

 

Summer/winter se Central heating temperature control knob

 

 

 

By turning this knob it is possible to choose the following operating modes: 

 

Summer (only DHW production) 

 

Winter (DHW production and central heating temperature control)  

 

 

When the switch is in the 

 (Summer) position the central heating mode is excluded. However, 

the frost protection mode remains enabled.  
 
 
 
 
 
 
With the knob in the position indicated in the figure, the boiler is in the “Winter” mode, and controls 
the  central  heating  hot  water  flow  temperature.  The  temperature  can  be  adjusted  between  30°C 
minimum and 80°C maximum.  

 

Summary of Contents for ViaKON 24 B

Page 1: ...17 2013 ...

Page 2: ...pliance or other objects The appliance is designed to be used in pumped hot water central heating systems and for domestic hot water production Any other use of this appliance will be considered improper VIADRUS declines any responsibility for any damages or injuries caused by an improper use in this case the risk is completely at the user s responsibility In order to use the appliance according t...

Page 3: ...s animals or damage to property The manufacturer shall not be held liable for any such injury and or damage 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must be carried out by a competent person and installed in accordance with the current standards and regulations Failure to correctly install this appliance could cause injury to persons animals or damage t...

Page 4: ...ressure gauge Summer winter selector Central heating temperature control knob By turning this knob it is possible to choose the following operating modes Summer only DHW production Winter DHW production and central heating temperature control When the switch is in the Summer position the central heating mode is excluded However the frost protection mode remains enabled With the knob in the positio...

Page 5: ...nk Power On indicator led This led will illuminate when the boiler is connected to the electricity supply Central heating mode indicator led This led will illuminate when there is a request for central heating If simultaneously there is a request for domestic hot water production the led will switch off Burner On indicator led When this led is illuminated it indicates that the burner is functionin...

Page 6: ...per scale the central heating hot water flow temperature is indicated On the lower scale the water pressure in the central heating system is indicated If the pressure is lower then 0 7 bar then it will be necessary to restore the correct pressure by operating the filling valve when the system is cold and the boiler not operating 6 2 CHECK LIST BEFORE COMMISSIONING THE BOILER Before commissioning t...

Page 7: ...inter in position 1 corresponds to the minimum temperature of 35 C the knob pointer in position 1 corresponds to the maximum temperature of 80 C SWITCH OFF OF THE BOILER Deactivation of heating mode By rotating the knob B completely to the left the heating is deactivated but the D H W mode remains active Summer mode Complete boiler shut down If the boiler is completely shut down the CH and DHW mod...

Page 8: ... metal systems Do not use anti frost products for motor vehicles because they could seriously damage the water gaskets If for any reason there is no gas or electrical supply the above described frost protection mode will not be active 6 5 ELIMINATING THE FAULTS If the boiler goes into lock out the user can reset the boiler only in the following cases Lock out led illuminated and flashing Cause Ins...

Page 9: ...ck is in the On position and that the air present in the piping has been vented Press the reset key to restore correct boiler operation If the cut off device operates repeatedly a maximum of 3 times causing boiler shutdown do not try to relight the boiler your self Contact your nearest VIADRUS authorized After Sales Service Centre WARNING If the boiler goes into lock out and or the leds continue t...

Page 10: ...ng factory The manufacturer requires for the guarantee applicability In the meaning of the Act No 222 94 Coll On conditions for business activities and government administration execution in certified branches and on Government Energy Inspection and ČSN 38 6405 amendment 1 5 99 EN 1775 to perform periodically 1 x year a gas boiler inspection Inspections may only be performed by an authorized organ...

Page 11: ...kaging unit EN 13429 NO 3 1 Recovery by material recycling ensure recyclability in all terms of the standard for the functional packaging unit EN 13430 YES 3 2 Recovery in the form of energy ensure that calorific gain is achievable for the functional packaging unit EN 13431 YES Iron NO 3 3 Recovery by composting ensure compost ability in all terms of the standard for the functional packaging unit ...

Page 12: ...ors of transcript or press Also reserves the right to bring those changes that will hold necessary to it own products or profits without jeopardizing its essential characteristics VIADRUS a s Bezručova 300 735 81 Bohumín Tel 420 596 083 050 Fax 420 596 082 822 www viadrus cz info viadrus cz ...

Reviews: