background image

POTTERTON

wall hung gas combination

boiler

THIS APPLIANCE IS FOR USE ON NATURAL GAS
ONLY

.

IT IS THE LAW THAT ALL GAS APPLIANCES ARE
INSTALLED

BY

A

COMPETENT

PERSON,

IN

A

C

CORDANCE WITH THE GAS SAFETY INSTALLA-

TION AND USE REGULATIONS 1984

.

I

NTRODUCTION

The information given in this booklet will help you to

obtain the maximum comfort from your appliance with
minimum trouble and cost

.

Your appliance has been designed to provide central

heating and domestic hot water directly from one unit.

The domestic hot water is produced instantaneously in
a special heat exchanger within the appliance (depend-

i

ng on the design layout of the DHW a delay may be

e

x

perienced on f

i

rst turning on the tap)

.

The electronic

control circuits have been designed uniquely so that the
temperatures of both the central heating and hot water
can be controlled to provide economic and safe use.
The burner automatically modulates its heat input to

meet the demand of your central heating or hot water.

ELECTRICITY SUPPLY

WARNING: THIS APPLIANCE MUST BE EARTHED.

Connection shall be made to a 240 Volts 50 Hz '

""

supply. If a mains plug connection

i

s used

i

t must be of

a three-pin type and fused to 3 Amps

.

To connect a plug (Fig. 1)

GREEN

/Y

ELLOW

EARTH

As the colour of the wires in the mains lead of the
app

l

iance may not

correspond with

the

coloured

markings identifying the terminals in your plug, proceed

as follows:-

The w

i

re which is coloured green-and-yellow must be

connected to the terminal in the plug which is marked
with the letter E or by the earth symbol

-::

E

-

or coloured

g

r

een or green-and

-

yellow.

The wire which is coloured blue must be con

nected to

the terminal which is marked with the

l

e

tter N or

coloured black.

The wire which is coloured b

r

own must be co

nnected to

the terminal which

i

s marked with the le

tter L or

coloured red

.

The boiler should have the min

i

mum clea

r

a

nces for

safety and maintenance as shown in F

i

g

. 2. If the

appliance is installed in a compartment do n

ot obstruct

any purpose-made ventilation opening, or

u

se

the com

-

partment for storage purposes, e.g

.

for foo

d

e

tc.

I

I

I

I

~

MIN 450mm

FROM FRONT OF

BOilER

POTTERTON

user's

guide

·

·

3735

Summary of Contents for Lynx Electronic

Page 1: ...r hot water ELECTRICITY SUPPLY WARNING THIS APPLIANCE MUST BE EARTHED Connection shall be made to a 240 Volts 50 Hz supply If a mains plug connection is used it must be of a three pin type and fused to 3 Amps To connect a plug Fig 1 GREEN YELLOW EARTH As the colour of the wires in the mains lead of the appliance may not correspond with the coloured markings identifying the terminals in your plug p...

Page 2: ...FF and the summer winter switch is set to winter 2 Ensurethat any time controls are in an ON condition and any room thermostat is calling for heat 3 Switch the boiler on off switch to ON The appliance will now operate in accordance with pre selected temperature demand set on the right hand temperature control knob The left hand control knob enables you to control the max temperature of the domesti...

Page 3: ...ility of freezing To avoid freezing three methods of protection can be used 1 Insulation of the applianceand pipework taking care not to impede any ventilation air supply 2 Leave the appliance running on the lowest room thermostat setting 3 Having a special low limit thermostat fitted Seek advice from your installer If a low limit thermostat has been fitted or the central heating is to be left run...

Page 4: ... The appliance does not operate on Central Heating The summer winter Switch on the boiler control panel is switched to summer Check that the summer winter switch is in the winter position Check that the time switch and room thermostat is switched on The appliance operates Ignition high Iow flc me lights flash on and OFF If this effect prevails for severalminutes the boiler must be switched off and...